Connection Requirements

Supported PLC Series

PLC-AESPLC-FBPLC-ES

Supported Data Registers

MXYKLFTCSZRQD@DConstant
S

Supported Flags

FlagBitSupport
ErrorF11.0
ZeroF11.1
CarryF11.2

Number of Steps

Steps
1

Operands

OperandDescription
SThis is the BOOL data register.
This is the bit number to toggle the contact ON/OFF.

When the bit is 0, the contact is OFF.
When the bit is 1, the contact is ON.

Notice

Notice for MapleLogic ANDF instruction.

Contact Orientation

The ANDF falling edge (one-shot) contact orientation behaves as follows:

  • The ANDF falling edge (one-shot) contact orientation is ON for 1 scan only.
    • The one-shot contacts turn ON at the falling edge of the assigned BOOL data register.
  • The one-shot contacts turn ON when the assigned BOOL data registers goes from ON to OFF.
Notice for MapleLogic ANDF instruction.

The one-shot contacts turn ON on the falling edge of an input signal or condition.

Ladder Diagram Examples

AND Gate Example

The ANDF falling edge (one-shot) contact orientation performs a boolean AND operation based on the ON status of the assigned BOOL data register, S, fo

The ANDF falling edge (one-shot) contact orientation performs a boolean AND operation based on the ON status of the assigned BOOL data register, S, for only 1 scan.

When the falling edge (one-shot) contact, M17.8, is powered OFF AND the falling edge (one-shot) contact, M10.4, is powered OFF, the coil, D86.4, is de

When the falling edge (one-shot) contact, M17.8, is powered OFF AND the falling edge (one-shot) contact, M10.4, is powered OFF, the coil, D86.4, is deenergized.

When the falling edge (one-shot) contact, M17.8, is powered ON AND the falling edge (one-shot) contact, M10.4, is powered OFF, the coil, D86.4, is dee

When the falling edge (one-shot) contact, M17.8, is powered ON AND the falling edge (one-shot) contact, M10.4, is powered OFF, the coil, D86.4, is deenergized.

When the falling edge (one-shot) contact, M17.8, is powered ON AND the falling edge (one-shot) contact, M10.4, is powered ON, the coil, D86.4, is ener

When the falling edge (one-shot) contact, M17.8, is powered ON AND the falling edge (one-shot) contact, M10.4, is powered ON, the coil, D86.4, is energized for only 1 scan.

The falling edge (one-shot) contacts, M17.8 and M10.4, will remain ON (unless otherwise specified), but the coil, D86.4, is deenergized after 1 scan.

The falling edge (one-shot) contacts, M17.8 and M10.4, will remain ON (unless otherwise specified), but the coil, D86.4, is deenergized after 1 scan.

Scan Execution Time

Since scan programs execute in less than a second, it might not appear that the coil, D86.4, was energized.

Both, or one one-shot, contact(s) turn ON at the rising edge of an input signal or condition.