The leader in industrial automation and control solutions

Instruction Parameters

Supported PLC Series

PLC-AESPLC-FBPLC-ES

Supported Data Registers

MXYKLFTCSZRQD@DConstant
S1
S2
D

Supported Flags

FlagBitSupport
ErrorF11.0
ZeroF11.1
CarryF11.2

Number of Steps

Steps
4

Operands

OperandDescription
S1The first operand.
Entries are WORD data registers or constants.

The signed value range is -32,768 ~ 32,767 (216).
The unsigned value range is 0 ~ 65,535 (216-1).
The Hexadecimal value range is H0000 ~ HFFFF.
S2The second operand.
Entries are WORD data registers or constants.

The signed value range is -32,768 ~ 32,767 (216).
The unsigned value range is 0 ~ 65,535 (216-1).
The Hexadecimal value range is H0000 ~ HFFFF.
DThe third operand.
Entries are only WORD data registers.
This is where the result of a logical S1 AND S2 is saved.

Notice

Error Flag (F11.0) Notice

The error flag, F11.0, will be ON for one scan when the address of the data register assigned by @D exceeds the range of the data register, D. The range of the data register, D, is dependent on the CPU type. F11.0 turns ON when the value of the data for a logical AND exceeds the data register assigned to S1 or S2.

Logical Operation

The WAND and WANDP instructions perform a logical AND on each bit of S1 and S2.

Notice for MapleLogic WAND/WANDP instruction.

Ladder Diagram Examples

WAND

The WAND instruction performs a logical AND on the WORD value, S1, and the WORD value, S2, and saves the result in an assigned WORD data register, D.

The WAND instruction performs a logical AND on the WORD value, S1, and the WORD value, S2, and saves the result in an assigned WORD data register, D.

When the contact, M0.0, is powered ON (1), a logical AND operation is performed on the WORD data registers, D0 and D2.

When the contact, M0.0, is powered ON (1), a logical AND operation is performed on the WORD data registers, D0 and D2. The result of the logical AND operation is saved in the WORD data register, D4.

Ladder Diagram Example for MapleLogic WAND/WANDP instruction.

Memory Monitor

Memory Monitor for MapleLogic WAND/WANDP instruction.

WANDP

The WANDP one-shot instruction performs a logical AND on the WORD value, S1, and the WORD value, S2, and saves the result in an assigned WORD data reg

The WANDP one-shot instruction performs a logical AND on the WORD value, S1, and the WORD value, S2, and saves the result in an assigned WORD data register, D. Every time this instruction energizes, it executes only once.

When the contact, M0.1, is powered ON (1), a logical AND operation is performed on the WORD data registers, D1 and D3.

When the contact, M0.1, is powered ON (1), a logical AND operation is performed on the WORD data registers, D1 and D3. The result of the logical AND operation is saved in the WORD data register, D5.

Ladder Diagram Example for MapleLogic WAND/WANDP instruction.

Memory Monitor

Memory Monitor for MapleLogic WAND/WANDP instruction.