The leader in industrial automation and control solutions

Thermocouple Module General Specifications

SpecificationDescriptionStandards
Operating Temperature-10°C ~ 65°C
14°F ~ 149°F
Storage Temperature-25°C ~ 80°C
-13°F ~ 176°F
Operating Humidity5% ~ 95% RH, Non-condensing
Storage Humidity5% ~ 95% RH, Non-condensing

Intermittent Vibration

FrequencyAccelerationAmplitudeTimes
5Hz ≤ f < 9Hz3.5mm10 times in X, Y, and Z
9Hz ≤ f ≤ 150Hz9.8m/s2 (1G)10 times in X, Y, and Z

Standard IEC 61131-2

Continuous Vibration

FrequencyAccelerationAmplitudeTimes
5Hz ≤ f < 9Hz1.75mm10 times in X, Y, and Z
9Hz ≤ f ≤ 150Hz4.9m/s2 (0.5G)10 times in X, Y, and Z

Standard IEC 61131-2

Shocks

DescriptionStandard
Maximum Shock Acceleration: 147m/s2 (15G)
Time: 11ms
Pulse Wave: Sine Half-Wave (3 times in X, Y, Z)
IEC 61131-2

Noise

SpecificationDescriptionStandard
Square Wave Impulse Noise±2kV
Electrostatic DischargeVoltage: 4kV (contact) 8kV (air)IEC 61131-2
IEC 61000-4-2
Radiated Electromagnetic Field80MHz ~ 1,000MHz
10V/m
IEC 61131-2
IEC61000-4-3

Fast Transient Burst Noise (Voltage)

Fast Transient Burst Noise (Voltage) TypeDescriptionStandard
CPU Power2kVIEC 61131-2
IEC 61000-4-4
Digital/Analog I/O (AC)2kVIEC 61131-2
IEC 61000-4-4
Digital/Analog I/O (DC)1kVIEC 61131-2
IEC 61000-4-4
Communication1kVIEC 61131-2
IEC 61000-4-4

Environment

No corrosive gas
No dust

Altitude

2,000m or less

Pollution

Pollution Degree 2 or less

Cooling

Natural air cooling

Thermocouple Module Physical Specifications

SpecificationIO-SA0400
Weight83g
Dimensions20mm x 63mm x 90mm
0.787in x 2.480in x 3.543in
Temperature Input Points4 Channels
Insulation MethodPhotocoupler Insulation between input terminal and PLC
No insulation between channels
Connection Terminal9-point terminal block
Current Consumption (Internal)DC:
3.3V
40mA
Current Consumption (External)DC:
24V
10mA

Thermocouple Module Performance Specifications

Thermocouple Type

K
J
E
T
B
R
S
N

Digital Conversion

Digitally Converted Value: 0 ~ 16,000 (-8,000 ~ 8,000) or -192 ~ 16,191 (-8,192 ~ 8,191)
Converted Temperature Value: Range of measured temperature (First decimal place value × 10)

Range of Temperature Input

Thermocuple TypesDIN codeRange of Measured Temperature (°C)Range of Measured Voltage (µV)
KITS-90-200.0 ~ 1,200.0-5,891 ~ 48,838
JITS-90-200.0 ~ 800.0-7,890 ~ 48,494
EITS-90-200.0 ~ 600.0-8,825 ~ 45,093
TITS-90-200.0 ~ 400.0-5,603 ~ 20,872
BITS-90400.0 ~ 1,800.0787 ~ 13,591
RITS-900.0 ~ 1,750.00 ~ 20,877
SITS-900.0 ~ 1,750.00 ~ 18,503
NITS-90-200.0 ~ 1,250.0-3,990 ~ 45,694
SpecificationDescription
RJCAutomatic
Wire Disconnection DetectionPer channel
Accuracy± [(Full scale) × 0.3% + 1°C (RJC Error)]
Maximum Conversion Rate50ms/4 Channels
Temperature Input Points4 Channels/1 Module
Insulation MethodPhotocoupler Insulation between input terminal and PLC
No insulation between channels
Connection Terminal9-point terminal block
Current Consumption (Internal)DC:
3.3V
40mA
Current Consumption (External)DC:
24V
90mA