High-Speed Counter (HSC)

Navigate to Online → Special Module Setup → HSC Module or click on the AD module within the Card Properties.

HSC Expansion Module Setup Card Properties in MapleLogic

Applied Modules

  • IO-SHSC02

HSC Module

HSC Expansion Module Setup HSC Setup in MapleLogic

Step 1: Hold CTRL to configure all channels at once.

Step 2: Click Setup to configure the counter modepreset valuecomparison 1 and 2 valuesring minimum and maximum valuecounter typesampling time, or pulse type.

Counter Mode

  • Linear Counter
  • Ring Counter

Counter Type

  • Not Count
  • Latch Count
  • Sampling Count
  • Interval Pulse Count

Pulse Type

  • 1-Ph. Multiple of 1
  • 1-Ph. Multiple of 1 (B-Ph. Sw)
  • 1-Ph. Multiple of 2
  • 1-Ph. Multiple of 2 (B-Ph. Sw)
  • CW/CCW
  • 2-Ph. Multiple of 1
  • 2-Ph. Multiple of 2
  • 2-Ph. Multiple of 4

Step 3: Once the settings are configured, click OK to confirm and apply the changes.

Step 4: To save the configured parameters to the PLC, click Write.

Step 5: Click Read to check the parameters.

Step 6: For real-time monitoring and module diagnostics, click Status. This displays the current value, minimum and maximum values, firmware version of the module, and any error codes.