The leader in industrial automation and control solutions

To write to buffer memory, use the TO instruction.

To read from buffer memory, use the FROM instruction

Please refer to the table below for writing to and reading from buffer memory.

MOD-SPOS02 Buffer Memory

X-Axis
(Hex)
X-Axis
(Dec)
Y-Axis
(Hex)
Y-Axis
(Dec)
DetailDescriptionReadWrite
46H7078H120Pulse Control Type
47H7179H121Bias Speed (Low)1pps ~ 100,000pps
48H727AH122Bias Speed (High)
49H737BH123Speed Limit (Low)1pps ~ 200,000pps
4AH747CH124Speed Limit (High)
4BH757DH125Acceleration/Deceleration Time 01ms ~ 65,535ms
4CH767EH126Acceleration/Deceleration Time 11ms ~ 65,535ms
4DH777FH127Acceleration/Deceleration Time 21ms ~ 65,535ms
4EH7880H128Acceleration/Deceleration Time 31ms ~ 65,535ms
4FH7981H129Reserved
50H8082H130Reserved
51H8183H131Software Upper Limit
(Low)
-2,147,483,648 ~ 2,147,483,647
52H8284H132Software Upper Limit
(High)
53H8385H133Software Lower Limit (Low)-2,147,483,648 ~ 2,147,483,647
54H8486H134Software Lower Limit (High)
55H8587H135Coordinate Indication Methodrefer below
56H8688H136Backlash Compensation0 ~ 65,535 Pulses
57H8789H137External Input Signal Function Selectionrefer below
58H888AH138JOG Speed Limit (Low)1pps ~ 200,000pps
59H898BH139JOG Speed Limit (High)
5AH908CH140JOG Acceleration/Deceleration TimeAcceleration or Deceleration Time
(0 ~ 3)
5BH918DH141Inching Speed0pps ~ 65,535pps
5CH928EH142Reserved
5DH938FH143Dwell Time0ms ~ 50,000ms
5EH9490H144Positioning Decision Completion Output Time0ms ~ 65,535ms
5FH9591H145Reserved
60H9692H146Reserved
61H9793H147Reserved
62H9894H148Reserved
63H9995H149Reserved
64H10096H150Origin Return Settingsrefer below
65H10197H151Origin Address (Low)-2,147,483,648 ~ 2,147,483,647
66H10298H152Origin Address (High)
67H10399H153Origin High-Speed Return (Low)0pps ~ 200,000pps
68H1049AH154Origin High-Speed Return (High)
69H1059BH155Origin Low-Speed Return (Low)0pps ~ 200,000pps
6AH1069CH156Origin Low-Speed Return (High)
6BH1079DH157Origin Return Acceleration/Deceleration Time (High)Acceleration or Deceleration Time
(0 ~ 3)

Pulse Control Type

Bit0123456789ABCDEF
FunctionNot Used: 0
Low Active: 1
High Active: 2
Not Used: 0
Low Active: 1
High Active: 2
XXXXXXXXXXXXXX

Coordinate Indication Method

  • The coordinate indication method is the position display during driving.
Bit0123456789ABCDEF
FunctionNo Update: 0
Update: 1
Update After Clearing: 2
No Update: 0
Update: 1
Update After Clearing: 2
XXXXXXXXXXXXXX

External Input Signal Function Selection

BitFunction
0External Upper & Lower Limit Function
Disable: 0
Enable: 1
1External Ready Signal
Disable: 0
Enable: 1
2External Inposition
Disable: 0
Enable: 1
3Not Used
4Not Used
5Not Used
6Not Used
7Not Used
8External Deceleration Limit Logic Selection
A Contact: 0
B Contact: 1
9External Acceleration Limit Logic Selection
A Contact: 0
B Contact: 1
AApproximate Origin Logic Selection
A Contact: 0
B Contact: 1
BOrigin Logic Selection
A Contact: 0
B Contact: 1
CNot Used
DNot Used
ENot Used
FNot Used

Origin Return Settings

Bit0123456789ABCDEF
FunctionExternal Upper & Lower Limit Function
Disable: 0
Enable: 1
External Ready Signal
Disable: 0
Enable: 1
External Inposition
Disable: 0
Enable: 1
XXXXX
Origin Return Direction
Forward: 0
Reverse: 1
XXXXXXX