PID Temperature Controller, 20-28VAC/11-40VDC, 9/64 DIN, Analog Retransmission, CT Input, Data Communications, Remote Setpoint

PID114-51110111
$225.00

The PID114-51110111 is a high-performance process and temperature controller with fuzzy logic, auto tuning, universal inputs, dual PID control, and built-in heater break detection. Its 2.8″ x 2.8″ panel mount design, precise 18-bit inputs, fast sampling, and Modbus RTU communications make it ideal for demanding industrial temperature and process control applications.

Share the product:

Volume Pricing

Planning a larger order? Let's talk about your pricing.

Quantity orders are priced case by case, around the configuration, volume, and delivery schedule you need. Tell our sales team what you have in mind and they will put a quote together for it. It is the quickest way to know exactly what your order will cost.

Power Details

Power Supply
20 to 28 VAC, 47-63 Hz / 11 to 40 VDC
Power Consumption
12VA, 6 W Maximum
Over Voltage Category
II

Signal Input

Type
Thermocouple (J, K, T, E, B, R, S, N, L, U, P, C, D), RTD(PT100(DIN), PT100(JIS)), Current(mA), Voltage (V, mV)
Resolution
18 bits
Sampling Rate
5 Times / Second (200 msec)
Maximum Rating
-2V DC minimum, 12 VDC maximum
Temperature Effect
±1.5 µV /°C for all inputs except mA input, ±3.0 µV /°C for mA
Sensor Lead Resistance Effect
Thermocouple: 0.2 µV /°Ω
3-wire RTD: 2.6 °C /Ω of Difference of Resistance of two leads
2-wire RTD: 2.6 °C /Ω of Sum of Resistance of two leads
Burn-out Current
200 nA
CMRR
120 dB
NMRR
55 dB
Sensor Break Detection
Sensor open for: Thermocouple, RTD, and mV inputs
Sensor short for: RTD Input
Below 1mA for: 4-20mA input
Below 0.25 VDC for: 1-5 VDC input
Not available for other inputs
Sensor Break Response Time
Within 4 seconds for: Thermocouple, RTD, and mV inputs
Within 0.1 seconds for: 4-20mA and 1-5 VDC inputs

Remote Set Point Input

Type
Linear Current, Linear Voltage
Range
-3mA to 27 mA, -1.3 VDC to 11.5 VDC
Accuracy
±0.05%
Remote Set Point Option
Available
Input Impedance
Current: 2.5 Ω, Voltage: 1.5 MΩ
Resolution
18 Bits
Sampling Rate
1.66 Times/Second
Maximum Rating
280 mA maximum for Current Input, 12 VDC Maximum for Voltage Input
Temperature Effect
±1.5 µV/°C for Voltage Input, ±3.0 µV/°C for Current Input
Sensor Break Detection
Below 1mA for 4-20 mA input
Below 0.25 VDC for 1-5 VDC input
Not available for other inputs
Sensor Break Response Time
0.1 Second

CT Input

Accuracy
±5% of Full-scale Reading ±1 Digit
Input Impedance
294 Ω
Measurement Range
0 to 50 AAC
Output of CT
0 to 5 VDC
Sampling Rate
1 Time/Second

Output 1/ Output 2

Type
Relay, Pulsed Voltage, Linear Voltage, or Linear Current
Relay Routing
2A,240 VAC, 200000 Life Cycles for Resistive Load
Pulsed Voltage
Source Voltage 5 VDC, Current Limiting Resistance 66 Ω
Linear Output Resolution
15 Bits
Linear Output Regulation
0.02% for full load change
Linear Output Setting Time
0.1 Sec (Stable to 99.9%)
Linear Output Ranges
0-22.2 mA (0-20 mA/4-20 mA), 0-5.55 VDC (0-5 VDC, 1-5 VDC), 0-11.1 VDC (0 – 10 VDC)
Isolation Breakdown Voltage
1000 VAC
Temperature Effect
±0.01% of Span/ °C
Load Capacity of Linear Output
Linear Current: 500Ω max., Linear Voltage: 10 KΩ min

Alarm

Relay Type
Form A
Maximum Rating
2A, 240 VAC, 200000 Life Cycles for Resistive Load
Alarm Functions
Dwell Timer, Deviation Low, Deviation High, Deviation In-Band, Deviation Out of Band, Process High, Process Low, Range High, Range Low, Range High Low
Profile Hold Back, Profile end, Heater Break, Heater Short, Event Input 1 & Event Input 2 controlled alarm Output
Alarm Mode
Latching, Hold, Normal, Latching/Hold, Setpoint Holding, Latching None Reset
Dwell Timer
0.1 to 4553.6 Minutes

Data Communication

Interface
RS-485
Protocol
Modbus RTU (Slave Mode)
Address
1 to 247
Baud Rate
2.8 KBPS to 115.2 KBPS
Parity Bit
None, Even, or Odd
Stop Bit
1 or 2 Bits
Data Length
7 or 8 Bits
Communication Buffer
160 Bytes

Analog Retransmission

Output Signal
4-20 mA, 0-20 mA, 0-10 VDC
Resolution
15 Bits
Accuracy
±0.05% of Span ± 0.0025%/ °C
Load Resistance
0 to 500 Ω for current output, 10 KΩ minimum for Voltage Output
Output Regulation
0.01% for full load change
Output Setting Time
0.1 Second (stable to 99.9%)
Isolation Breakdown
1000 VAC min
Integral Linearity Error
±0.005% of span
Temperature Effect
±0.0025% of span/°C
Saturation Low
0 mA or 0 VDC
Saturation High
22.2 mA or 5.55 V, 11.1 V min
Linear Output Ranges
0-22.2 mA (0-20 mA/4-20 mA), 0-5.55 VDC (0-5 VDC, 1-5 VDC), 0-11.1 VDC (0 – 10 VDC)

User Interface

Keypad
4 Keys
Display Type
4 Digit LCD Display
No. of Displays
3
Upper Display Size
0.58” (15 mm)
Lower Display Size
0.32” (8.3 mm)

Programming Port

Interface
Micro USB
PC Communication Function
Firmware upgrade

Control Mode

Output 1
Reverse (Heating) or Direct (Cooling) Action
Output 2
PID cooling control, Cooling P band 50~300% of PB, Dead band -36.0 ~ 36.0% of PB
ON-OFF
0.1~50.0 °C (0.1~90.0 °F) hysteresis control (P band = 0)
P or PID
0 – 100.0% offset adjustment
PID
Fuzzy logic modified Proportional band 0.1 ~ 500.0 °C (0.1~900.0 °F), Integral time 0 – 3600 Secs, Derivative Time 0 – 360.0 Secs
Cycle Time
0.1 to 90.0 Seconds
Manual Control
Heat (MV1) and Cool (MV2)
Auto-Tuning
Cold Start and Warm Start
Failure Mode
Auto transfer to manual mode while sensor break or A-D Converter damage
Ramping Control
0 to 500.0 °C (0 to 900.0 °F)/Minute or 0 to 500.0 °C (0 to 900.0 °F)/Hour Ramp Rate

Digital Filter

Function
First Order
Time Constant
0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 Seconds, Programmable

Mechanical

Dimensions WxHxD
2.8 x 2.8 x 2.3” [72 x 72 x 59mm]
Panel Cutout (inches) [mm]
2.63 x 2.63” [66.8 x 66.8mm]
Weight
0.42 lbs [190g]
Mounting
Panel mount
Construction
Flame Retardant Polycarbonate
DIN Size
9/64
Depth Behind Panel
1.97” [50mm]

Environmental

Shock Resistance
200 m/s2 (20g)
Vibration Resistance
10 to 55 Hz, 10 m/s2 for 2 Hours
Altitude (Air Pressure)
Up to 2,000 Meters (~80 kPa)
Operating Temperature
14° ~ 122°F (-10° ~ 50°C)
Storage Temperature
-40°F~140°F (-40°C~60°C)
Humidity
0 to 90% RH (Non-Condensing)
Certifications
CE/ RoHS/ cULus/ REACH
Pollution
Degree II
Insulation Resistance
20 MΩ Minimum (@500 VDC)
Dielectric Strength
2000 VAC, 50/60 Hz for 1 Minute
EMC
EN61326
Protective Class
IP50 front panel, IP20 rear terminals & housing. Indoor use.

How do you tune a PID controller?

Start with auto-tuning if your controller supports it, or tune manually by adjusting proportional gain, the integral term, and the derivative term while watching the system response. Classic methods include the Ziegler-Nichols method, the Cohen-Coon method, and the relay method.

Products:

Manuals and Guides:

Technical Articles:

How does a PID controller work?

A PID controller compares the process variable (the measured value) to the set point (the desired value) to calculate the error. It then uses proportional, integral, and derivative calculations to determine the appropriate control output. This signal adjusts a control element, such as a valve or motor, while sensor feedback allows the controller to continuously monitor the process and correct deviations from the set point.

Products:

Manuals and Guides:

Technical Articles:

What is the difference between PI and PID control?

PI control uses proportional and integral terms to correct error and eliminate steady-state error. PID control adds derivative action, which responds to the rate of change of error to help reduce overshoot and improve stability. However, derivative action can amplify measurement noise and is not beneficial for every process.

Products:

Manuals and Guides:

Technical Articles:

What certifications do the PID100 series controllers have?

Maple Systems PID100 Series controllers are CE certified, cULus listed, and comply with RoHS and REACH requirements. They also meet EMC standard EN61326:

Certification: cULus
Compliance: RoHS and REACH
EMC: EN61326
Front panel protection: IP50
Rear terminal and housing protection: IP20

PID100 Series controllers are designed for indoor use and have an operating temperature range of 14°F to 122°F (-10°C to 50°C).

Products:

Manuals and Guides:

Technical Articles:

Do the PID100s support Modbus communications?

Yes, select Maple Systems PID100 Series controllers include built-in RS-485 communication and support Modbus RTU in slave mode.

Communication settings include:
Device addresses: 1 to 247
Baud rate: Configurable
Parity: None, even. or odd
Stop bits: One or two
Data length: Seven or eight bits

This allows the PID controller to exchange process and control data with compatible industrial automation equipment using Modbus RTU.

Products:

Manuals and Guides:

Technical Articles:

What sensors work with the PID100 Series?

The Maple Systems PID100 Series support multiple sensors and process input types for PID temperature and process control applications.

Supported inputs include:
Thermocouples: J, K, T, E, B, R, S, N, L, U, P, C, and D
RTD: PT100 DIN and PT100 JIS
Current inputs: Current process signals, including 4-20 mA
Voltage inputs: Voltage and millivolt signals

The PID100 Series also includes sensor break detection for supported thermocouple, RTD, millivolt, current, and voltage inputs.

Products:

Manuals and Guides:

Technical Articles:

What is the difference between PID111 and PID114?

PID111s and PID114s are part of the Maple Systems PID100 Series and support universal inputs, fuzzy logic PID control, auto-tuning, flexible control outputs, and Modbus RTU communication.

The main differences are size and available features:

PID111: Compact 1/32 DIN controller with two 4-digit displays
PID114: Larger 9/64 DIN controller with three 4-digit displays
Heater break detection: Available on PID114s through a CT input
Remote set point input: Available as an option on PID114s
Panel cutout: PID111 uses a 45 x 22.2 mm cutout, while PID114 uses a 68 x 68 mm cutout

Choose the PID111s when panel space is limited and the additional PID114 features are not required. Choose the PID114 when your application needs heater monitoring, remote set point capability, or the larger display format.

Products:

Manuals and Guides:

Technical Articles:

What is the panel cutout size for a PID111?

For Installation:
Panel cutout: 1.77 x 0.88″
Controller dimensions: 1.89 x 0.95 x 3.6″
Depth behind panel: Approximately 84 mm

Always verify the current product datasheet before machining the panel opening.

Products:

Manuals and Guides:

Technical Articles:

What is the panel cutout size for a PID114?

The PID114 is a 9/64 DIN panel-mount PID Controller.

For Installation:
Panel cutout: 68 x 68 mm
Controller dimensions: 72 x 72 x 59 mm
Depth behind panel: Approximately 50 mm
Recommended panel thickness: 1 to 5 mm

Always verify the current product datasheet before machining the panel opening.

Products:

Manuals and Guides:

Technical Articles:

When you order the PID114-51110111 the following items are included in the box:

  • PID114-51110111
  • Mounting Adapter
  • Quick Start Guide
  • Warranty Statement

Have you used this product? Share your thoughts and help others make the best choice!

Leave a Review