Power Supply, AC/DC, C1D2, Industrial Economical, DIN Rail, 24VDC, 6.5A/230VAC or 5.2A/115VAC, 156W/230VAC or 125W/115VAC
Power your Maple Systems product with this Economical Industrial, DIN-rail mountable power supply, providing 24VDC, 6.5A/230VAC or 5.2A/115VAC, & 156W/230VAC or 125W/115VAC. EDR-150-24 (Formerly 4010-0021)
- US-based technical support.
- Universal AC Input / Full Range
- Protections: Short Circuit / Overload / Over Voltage / Over Temperature
- Cooling by Free Air Convection
- DIN Rail TS-35/7.5 or 15 Compatible
- UL508 (industrial control equipment) approved
- BS EN/EN61000-6-2 (BS EN/EN50082-2) industrial immunity level
- 100% full load burn-in test
Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case of adjacent device is a heat source, 15mm clearance is recommended on the left and right side
OEM
| Mean Well | EDR-150-24 |
|---|
Output
| DC Voltage | 24 V |
|---|---|
| Rated Current | 6.5 A/230 VAC – 5.2 A/115 VAC |
| Current Range | 0 ~ 6.5 A/230 VAC – 0 ~ 5.24 A/115 VAC |
| Rated Power | 156 W/230 VAC – 125 W/115 VAC |
| Peak: Current (5 sec.) | N/A |
| Peak: Power (5 sec.) | N/A |
| Ripple & Noise (max.) | 150mVp-p |
| Voltage Adj. Range | 24 ~ 28 V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 1500 ms, 60 ms/230 VAC – 3000 ms, 60 ms/115 VAC at full load |
| Hold Up Time (Typ.) | 16 ms/230 VAC – 10 ms/115 VAC at full load |
Input
| Voltage Range | AC: 90 ~ 264 VAC – DC: 127 ~ 370 VDC
|
|---|---|
| No Load Power Consumption with Remote Power (RP): RP OFF | N/A |
| No Load Power Consumption with Remote Power (RP): RP ON | N/A |
| Frequency Range | 47 ~ 63 Hz |
| Power Factor (Typ.) | PF>0.98/115 VAC – PF>0.95/230 VAC – PF>0.9/277 VAC at full load |
| Efficiency (Typ.) | 87% |
| AC Current (Typ.) | 2.6 A/115 VAC – 1.7 A/230 VAC |
| Inrush Current (Typ.) | COLD START 20 A / 115 VAC – 35 A / 230 VAC |
| Leakage Current | <1 mA/240 VAC |
Protection
| Overload | 105 ~ 130% rated output power Constant current limiting, recovers automatically after fault condition is removed / 230 VAC 105 ~ 150% rated output power Constant current limiting, recovers automatically after fault condition is removed / 115 VAC Hiccup mode at 90 ~ 100 VAC, recovers automatically after fault condition is removed |
|---|---|
| Over Voltage | Protection type: Shut down o/p voltage, re-power ON to recover Max. 29 ~ 33 V |
| Over Temperature | Shut down o/p voltage, re-power on to recover |
Function
| Parallel (Droop Mode) | N/A |
|---|---|
| Remote Control | Power ON: N/A Power OFF: N/A |
| MODBus Interface | N/A |
| Transient Peak Current Capability | N/A |
Mechanical
| Terminal Connector Type | Screw-based Connector |
|---|---|
| Dimensions WxHxD | 40 x 125.2 x 113.5 mm |
| Weight | ~ 1.32 lbs [600 g] |
| Mean Time Between Failures (MTBF) | 2717.1K hrs min. Telcordia SR-332 (Bellcore) 472.5K hrs min. MIL-HDBK-217F (25 °C) |
Environmental
| Storage Temperature | -40 °F ~ 185 °F (-40 °C ~ 85 °C) |
|---|---|
| Storage Humidity | 10 ~ 95% RH non-condensing |
| Temperature Coefficient | ±0.03%/°C (0 ~ 50 °C) |
| Vibration | Component:10 ~ 500 Hz, 2G 10 min./1 cycle, 60 min. each along X, Y, Z axis; Mounting: Compliance to IEC60068-2-6 |
| Working Temperature | -20 ~ +60 °C (Refer to "Derating Curve") |
| Working Humidity | 20 ~ 95% RH non-condensing |
Safety & EMC
| Certifications | EAC: TPTC004 EAC: TPTC020 BSMI: CNS15598-1 UL508 TUV BS EN/EN62368-1 |
|---|---|
| Withstand Voltage | I/P-FG: 2 kVAC O/P-DC OK: 0.5 kVAC I/P-O/P: 3 kVAC |
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500 VDC/25 °C/ 70%RH |
| EMC Emission (Parameter/Standard/Test Level) | Conducted: BS EN/EN55032 (CISPR32) – Class A Harmonic Current: BS EN/EN61000-3-2 – Class A (≦80% Load) Voltage Flicker: BS EN/EN61000-3-3 CNS15936 Class A |
| EMC Immunity (Parameter/Standard/Test Level) | BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020 |
What is the difference between peak power and rated power?
Rated power is the continuous amount of power a power supply is designed to deliver under specified operating conditions. Peak power is the higher output level that a power supply can temporarily provide to accommodate short-duration increases in demand.
For example, a 240W power supply with 200% peak power capability may temporarily deliver up to 480W under the manufacturer’s specified conditions. This can be useful when powering equipment with high startup currents, such as motors, Solenoids, and capacitive loads.
Peak Power is not intended for continuous operation.
Products:
Articles & Case Studies
What is the formula used to figure out Watts?
By multiplying Volts (V) with Amps (A), you can figure out Watts (A). You can rearrange the basic electrical power equation depending on what you need to solve:
Watts = Volts x Amps
Amps = Watts ÷ Volts
Volts = Watts ÷ Amps
Products:
Articles & Case Studies
How do I choose the right DIN Rail power supply?
Choose a power supply based on your equipment’s required DC output voltage, total current consumption, power rating, AC input voltage and operating environment. Allow additional capacity for startup surges and future system expansion. Also consider temperature ratings, available cabinet space, and any required safety certifications.
Products:
Articles & Case Studies
What does DC OK signal indicate on your DIN Rail power supplies?
The DC OK signal indicates whether the power supply’s DC output is operating within its specified voltage range.
Depending on the model, this indication may be provided through the LED, relay contact, or a communication interface. It can be connected to a PLC or monitoring system to help identify power supply faults or abnormal output conditions.
This feature is especially useful in industrial applications where monitoring power availability is important for system reliability.
Products:
Articles & Case Studies
What is a DIN Rail power supply?
A DIN Rail power supply converts AC input voltage into regulated DC power for industrial automation equipment, including PLCs, HMIs, sensors, relays and other control components. It mounts directly onto a standard DIN rail inside an Electrical control cabinet.
Products:
Articles & Case Studies
What is the difference between single-phase and three-phase DIN rail power supplies?
Single-phase power supplies operate from a single-phase AC input, commonly used in smaller industrial control panels and automation systems. Three-phase power supplies accept three-phase AC input, making them suitable for larger industrial installations with higher power requirements.
Products:
Articles & Case Studies
What protection features are built into your DIN Rail power supplies?
Our DIN Rail power supplies include built-in protection features designed to help protect the power supply and connected equipment from electrical faults. Depending on the model, these may include:
- Short-Circuit Protection: Helps prevent damage when the output terminals are shorted.
- Overload Protection: Limits output current or shuts down the supply when connected equipment draws excessive power.
- Overvoltage Protection: Helps prevent excessive output voltage from damaging connected devices.
- Overtemperature Protection: Protects the power supply if internal temperatures exceed safe operating limits.
These protections help improve system reliability and reduce the risk of equipment damage.
Products:
Articles & Case Studies


