Power Supply, AC/DC, DIN Rail, Ultra Slim Industrial, Three-Phase, 24VDC, 40A, 960W

PS24DB960
$350.00

Power your Maple Systems product with this Three-Phase DIN-rail mountable power supply, providing 24VDC, 40A, & 960W. XTR-960-24

Share the product:

Volume Pricing

Planning a larger order? Let's talk about your pricing.

Quantity orders are priced case by case, around the configuration, volume, and delivery schedule you need. Tell our sales team what you have in mind and they will put a quote together for it. It is the quickest way to know exactly what your order will cost.

OEM

Mean Well
XTR-960-24

Output

DC Voltage
24V
Rated Current
40A
Current Range
0 ~ 40A
Rated Power
960W
Peak: Current (5 sec.)
80A
Peak: Power (5 sec.)
1920W
Ripple & Noise (max.)
120mVp-p
Voltage Adj. Range
24 ~ 29V
Voltage Tolerance
±1.0%
Line Regulation
±0.5%
Load Regulation
±1.0%
Setup, Rise Time
800ms, 60ms/400Vac – 600ms, 60ms/500Vac at full load
Hold Up Time (Typ.)
20ms/400Vac – 20ms/500Vac at full load

Input

Voltage Range
Three-Phase 320 ~ 600Vac (Dual phase operation possible) 450 ~ 800Vdc

Voltage Range: Three-Phase 320 ~ 600Vac (Dual phase operation possible) 450 ~ 800Vdc

Dual phase operation is allowed under certain derating to output load. Please refer to derating curves for details.

No Load Power Consumption (Typ.)
N/A (See No Load Power Consumption with Remote Power)
No Load Power Consumption with Remote Power (RP): RP OFF
3.1W @ 400Vac
No Load Power Consumption with Remote Power (RP): RP ON
6.5W @ 400Vac
Frequency Range
47~ 63Hz
Power Factor (Typ.)
PF≧0.92/400Vac PF≧0.9/500Vac at full load
Efficiency (Typ.)
95%
AC Current (Typ.)
2A/400Vac – 1.4A/500Vac
Inrush Current (Typ.)
COLD START 10A/500Vac
Leakage Current
<3.5mA / 530Vac

Protection

Overload
105%~200% rated output power for more than 5 sec then constant current limiting without shutdown at rate current when Vo=30%~100%
Over Voltage
Protection type: Shut down o/p voltage, re-power ON to recover
Max. 30 ~ 35V
Over Temperature
Protection type: Shut down o/p voltage, recover automatically after temperature goes down

Function

Parallel (Droop Mode)
Up to 3840W (3+1) units, please refer to Function Manual below for more details
DC OK Relay Contact
Relay Contact Ratings (max.): 30Vdc/1A, 30Vac/0.5A resistive load
Remote Control
Power ON: RC + ~ RC- open or keep 2~5Vdc
Power OFF: RC + ~ RC- short or keep<0.5Vdc
MODBus Interface
N/A
Transient Peak Current Capability
N/A

Mechanical

Terminal Connector Type
Screw-based Connector
Dimensions WxHxD
96 x 125.2 x 132mm
Weight
~ 4.80 lbs [2180g]
Mean Time Between Failures (MTBF)
936.0K hrs min. Telcordia SR-332 (Bellcore)
117.5K hrs min. MIL-HDBK-217F (25°C)

Environmental

Storage Temperature
-40°F~185°F (-40°C~85°C)
Storage Humidity
10 ~ 95% RH non-condensing
Temperature Coefficient
±0.03%/°C (0 ~60°C)
Vibration
Component:10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axis; Mounting: Compliance to IEC60068-2-6
Working Temperature
-40 ~ +85°C (Refer to "Derating Curve")

Working Temperature: -40 ~ +85°C (Refer to "Derating Curve")

See page 4 of datasheet for "Derating Curve" (Load vs Ambient Temp.)

Working Humidity
20 ~ 95% RH non-condensing

Safety & EMC

Certifications
CB: IEC 62368-1, IEC 61558-1/2-16, IEC 61010-1/-2-201
TUV: BS EN/EN 62368-1, BS EN /EN 61558-1/-2-16, BS EN/EN 61010-1/-2-201
CCC: GB4943.1
BSMI: CNS15598-1
EAC: TPTC004 approved
UL: UL121201/CSA C22.2 NO.213.17 Class I, DIV2 Group A,B,C,D Hazardous Locations T4; UL61010-1/-2-201
SEMI F47: Approved
Over Voltage Category
IEC/EN 61558-1/-2-16 (OVC Ⅲ, altitude up to 2000m )
IEC/EN/UL 61010-1/-2-201 (OVC Ⅱ, altitude up to 5000m )
IEC/EN 62368-1 (OVC Ⅱ, altitude up to 5000m )
Safety Extra-Low Voltage (SELV)
IEC/EN 61558-2-16 (SELV )
IEC/EN 62368-1 (SELV / ES1 )
Withstand Voltage
O/P-DC OK: 0.5KVac
I/P-O/P: 4.87KVac
I/P-FG: 2.5KVac
O/P-FG: 0.5KVac
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25°C/ 70%RH
EMC Emission (Parameter/Standard/Test Level)
Conducted: BS EN/EN55032 (CISPR32) / BS EN/EN61204-3 / CNS15936 / KS C 9832 – Class B
Radiated: BS EN/EN55032 (CISPR32) / BS EN/EN61204-3 / CNS15936 / KS C 9832 – Class B
Harmonic Current: BS EN/EN61000-3-2 – Class A
Voltage Flicker: BS EN/EN61000-3-2 – N/A
EMC Immunity (Parameter/Standard/Test Level)
Radiated: BS EN/EN61000-4-3 – Level 3, 10V/m; criteria A
Surge: BS EN/EN61000-4-5 – Level 4, 2KV/Line-Line; Level 4, 4KV/Line-Line-Chassis; criteria A
Conducted: BS EN/EN61000-4-6 – Level 3, 10V; criteria A
Magnetic Field: BS EN/EN61000-4-8 – Level 4, 30A/m; criteria A
Voltage Dips and Interruptions: N/A – N/A
BS EN/EN55035, BS EN/EN61204-3, BS EN/EN61000-6-2 (BS EN/EN50082-2), KS C 9835, SEMI F47 tested at 200Vac
ESD: BS EN/EN61000-4-2 – Level 4, air 15KV ; Level 4, 8KV contact; criteria A
EFT/Burst: BS EN/EN61000-4-4 – Level 4, 4KV ; criteria A
Voltage Dips and Interruptions: BS EN/EN61000-4-11 – >95% dip 0.5 periods, 30% dip 25 periods> 95% interruptions 250 periods

What is the difference between peak power and rated power?

Rated power is the continuous amount of power a power supply is designed to deliver under specified operating conditions. Peak power is the higher output level that a power supply can temporarily provide to accommodate short-duration increases in demand.

For example, a 240W power supply with 200% peak power capability may temporarily deliver up to 480W under the manufacturer’s specified conditions. This can be useful when powering equipment with high startup currents, such as motors, Solenoids, and capacitive loads.

Peak Power is not intended for continuous operation.

What is the formula used to figure out Watts?

By multiplying Volts (V) with Amps (A), you can figure out Watts (A). You can rearrange the basic electrical power equation depending on what you need to solve:

Watts = Volts x Amps

Amps = Watts ÷ Volts

Volts = Watts ÷ Amps

Products:

How do I choose the right DIN Rail power supply?

Choose a power supply based on your equipment’s required DC output voltage, total current consumption, power rating, AC input voltage and operating environment. Allow additional capacity for startup surges and future system expansion. Also consider temperature ratings, available cabinet space, and any required safety certifications.

Control Cabinet with Maple Systems HMI, PLC, Tower Stack Light and Power Supply
What does DC OK signal indicate on your DIN Rail power supplies?

The DC OK signal indicates whether the power supply’s DC output is operating within its specified voltage range.

Depending on the model, this indication may be provided through the LED, relay contact, or a communication interface. It can be connected to a PLC or monitoring system to help identify power supply faults or abnormal output conditions.

This feature is especially useful in industrial applications where monitoring power availability is important for system reliability.

What is a DIN Rail power supply?

A DIN Rail power supply converts AC input voltage into regulated DC power for industrial automation equipment, including PLCs, HMIs, sensors, relays and other control components. It mounts directly onto a standard DIN rail inside an Electrical control cabinet.

Products:

What is the difference between single-phase and three-phase DIN rail power supplies?

Single-phase power supplies operate from a single-phase AC input, commonly used in smaller industrial control panels and automation systems. Three-phase power supplies accept three-phase AC input, making them suitable for larger industrial installations with higher power requirements.

What protection features are built into your DIN Rail power supplies?

Our DIN Rail power supplies include built-in protection features designed to help protect the power supply and connected equipment from electrical faults. Depending on the model, these may include:

  • Short-Circuit Protection: Helps prevent damage when the output terminals are shorted.
  • Overload Protection: Limits output current or shuts down the supply when connected equipment draws excessive power.
  • Overvoltage Protection: Helps prevent excessive output voltage from damaging connected devices.
  • Overtemperature Protection: Protects the power supply if internal temperatures exceed safe operating limits.

These protections help improve system reliability and reduce the risk of equipment damage.