Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Parker Hannifin SLVD Series. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
Supported Series: Parker SLVD Servo, SLVD1N, SLVD2N, SLVD5N, SLVD7N,
HMI Settings
| Parameters | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | Parker SLVD Series | ||
| PLC I/F | RS485 4W | ||
| Baud rate | 9600 | 9600/19200 | |
| Data bits | 8 | 7, 8 | |
| Parity | Even | Even, Odd, None | |
| Stop bits | 1 | 1, 2 | |
| PLC sta. no. | 0 | 0–31 | |
| Online simulator | YES |
Device Address
| Bit/Word | Device type | Format | Range | Memo |
|---|---|---|---|---|
| B | Par_Binary |
DDDDdd |
0 ~ 999915 | Set bit parameter |
| W | Par_One_Word |
DDDD |
0 ~ 9999 | Set 2 bytes parameter |
| DW | Par_Two_Word |
DDDD |
0 ~ 9999 | Set 4 bytes parameter |
| W | Par_One_Byte |
DDDD |
0 ~ 9999 | Set 1 byte parameter |
| W | RESET |
D |
0 | |
| W | RUN |
D |
0 |
Wiring Diagram
NOTE: The serial port pin assignments may vary between HMI models.
RS-485 4W
| HMI | Direction | PLC |
|---|---|---|
| Pin assignments | RS485 4W 15P D-Sub Male |
|
| Rx- | ↔ (bidirectional) | 7 TX- |
| RX+ | ↔ (bidirectional) | 12 TX+ |
| Tx- | ↔ (bidirectional) | 2 RX- |
| Tx+ | ↔ (bidirectional) | 1 RX+ |
| ↕︎ (tie) | 6 TER | |
| GND | ↔ (bidirectional) | 3 GND |