The leader in industrial automation and control solutions

Introduction

All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Cimon CM3-SP32MDT/SP16MDR/V/E/F (Ethernet). Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Supported Series: CM3-SP32MDT/SP16MDR/V/E/F

Website: https://www.cimon.com/

HMI Settings

ParametersRecommendedOptionsNotes
PLC typeCimon CM3-SP32MDT/SP16MDR/V/E/F(Ethernet)
PLC I/FEthernetUse UDP
Port no.10266

Device Address

Bit/WordDevice typeFormatRangeMemo
BXDDh0 ~ 63F
BYDDh0 ~ 63F
BMDDDh0 ~ 511F
BLDDDh0 ~ 255F
BKDDDh0 ~ 255F
BFDDDh0 ~ 127F
BTDDD0 ~ 511
BCDDD0 ~ 511
BQDDDh0 ~ 511F
WS_BitDDDD0 ~ 9999
WSDD0 ~ 99
WRDD0 ~ 15
WDDDDD0 ~ 9999
WZDDDD0 ~ 1063
WTCDDDD0 ~ 1023
WTSDDDD0 ~ 1023
WCCDDDD0 ~ 1023
WCSDDDD0 ~ 1023

Wiring Diagram

The diagram below shows the Ethernet cable wiring.

Standard Ethernet straight-through cable wiring diagram showing T568B color-coded pairs on both ends.