All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Toshiba TOSVERT VF (EtherNet/IP). Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Supported Series: TOSHIBA TOSVERT VF (EtherNet/IP)

Website: http://www.toshiba-machine.co.jp

HMI Settings

ParametersRecommendedOptionsNotes
PLC typeTOSHIBA TOSVERT VF (EtherNet/IP)
PLC I/FEthernet
Port no.44818

Identity Object Reference

Adding Tags in EBPro (EasyBuilder)

Click **Tag Manager** when adding this driver to initiate tag information. To edit an address tag, see the factory manual.nn. The following is an example of how to add Vendor ID in Tag Editor. See section 3.2.3 Identity Object in the factory manual for details on this ID.

  1. Open Tag Manager

    In System Parameter Settings, select the TOSHIBA TOSVERT VF (EtherNet/IP) device, then click Tag Manager to open the EthernetIp Setting dialog.
    System Parameter Settings dialog in EasyBuilder Pro showing the Tag Manager button highlighted for adding TOSVERT VF driver tags.
  2. Add the Vendor ID tag

    Under Struct-Defined, select Identity to add Vendor_ID. The notation {1,1,1} represents {Class code, Instance ID, Attribute ID}. Enter UINT in the Data Type field according to the factory manual. When finished, this data member can be found in Identity Object.
    EasyBuilder Pro EtherNet/IP Setting dialog showing the Add button to add a new tag with Vendor ID class attribute selected.

Note: The Identity Object (Class Code: 01HEX) is used to identify the EtherNet/IP adapter on the network. The Instance Attributes for the TOSVERT VF adapter are shown in the following table from the factory manual.

Factory manual table showing Identity Object Instance Attributes including Vendor ID (741, Crevis Co. Ltd), Device Type (0C HEX, Communications Adapter), Product Code (512, NA-9188), and Revision (Major 1–9, Minor 1–255).

Supported Device Types

Data TypeEasyBuilder Data FormatMemo
Boolbit
Byte16-bit BCD, Hex, Binary, Unsigned8-bit
SInt16-bit BCD, Hex, Binary, Signed8-bit
USInt16-bit BCD, Hex, Binary, Unsigned8-bit
Word16-bit BCD, Hex, Binary, Unsigned16-bit
Int16-bit BCD, Hex, Binary, Signed16-bit
UInt16-bit BCD, Hex, Binary, Unsigned16-bit
DWord32-bit BCD, Hex, Binary, Unsigned32-bit
DInt32-bit BCD, Hex, Binary, Signed32-bit
Real32-bit Float32-bit
UDInt32-bit BCD, Hex, Binary, Unsigned32-bit
ArrayWord array for ASCII input and displayLength=word

Wiring Diagram

NOTE: Use a standard straight-through Ethernet cable to connect the HMI to the TOSVERT VF drive.

The diagram below shows the Ethernet cable wiring.

Straight-through Ethernet cable wiring diagram showing all 8 pins connected pin-to-pin: W/Orange, Orange, W/Green, Blue, W/Blue, Green, W/Brown, Brown.