All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with LS Electric Metronix AnyPack. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Protocol: LS Mecapion Metronix AnyPack

HMI Settings

Parameters Recommended Options Notes
PLC type LS Mecapion Metronix AnyPack
PLC I/F RS232
Baud rate 9600
Data bits 8
Parity None
Stop bits 1
PLC sta. no. 0

Device Address

Bit/Word Device Type Format Range Memo
B MD_Low_16bit DDDDDdd 0 ~ 9999915
B MD_High_16bit DDDDDdd 0 ~ 9999915
B MD_Low_16bit_s DDDDDdd 0 ~ 9999915
B MD_High_16bit_s DDDDDdd 0 ~ 9999915
DW MD DDDD 0 ~ 9999
DW MD_WSS DDDD 0 ~ 9999

Wiring Diagram

NOTE: The serial port pin assignments may vary between HMI models.

RS-232

HMI Direction PLC
Pin assignments RS232
Terminal
Rx ↔ (bidirectional) 6
Tx ↔ (bidirectional) 5
GND ↔ (bidirectional) GND 11
GND 12