Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with HUST H4X. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
Supported Series: HUST CNC Controller H4 Series
Website: http://www.hust.com.tw/
HMI Settings
| Parameter | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | HUST H4X | ||
| PLC I/F | RS-232 | CPU port | |
| Baud rate | 38400 | 9600, 19200, 38400, 57600 | |
| Data bits | 7 | ||
| Parity | Even | ||
| Stop bits | 2 | ||
| Turn around delay | 5 | ||
| PLC sta. no. | 1 |
Device Address
| Bit/Word | Device Type | Format | Range | Memo |
|---|---|---|---|---|
| B | I | DDD | 0 ~ 255 | Mapping to VM 10800 ~ 10807 (read only) |
| B | O | DDD | 0 ~ 255 | Mapping to VM 10808 ~ 10815 (read only) |
| B | C | DDD | 0 ~ 255 | Mapping to VM 10816 ~ 10823 (read only) |
| B | S | DDD | 0 ~ 255 | Mapping to VM 10824 ~ 10831 (read only) |
| B | A | DDD | 0 ~ 255 | Mapping to VM 10832 ~ 10863 (read only) |
| B | VM_bit | DDDDDdd | 100 ~ 9999931 | Bit address (dd): 00 ~ 31 |
| DW | VM | DDDDD | 1 ~ 99999 | Please refer to the controller specification for register range. |
| DW | R | DDD | 0 ~ 255 | Mapping to VM 10000 ~ 10255 (read only) |
| DW | Cn | DDD | 0 ~ 255 | Mapping to VM 10256 ~ 10511 (read only) |
| DW | Tm | DDD | 0 ~ 255 | Mapping to VM 10512 ~ 10767 (read only) |
Wiring Diagram
NOTE: The serial port pin assignments may vary between HMI models.
RS-232
| HMI | Direction | PLC |
|---|---|---|
| Pin assignments | RS232 9P D-Sub Male |
|
| Rx | ↔ (bidirectional) | 2 |
| Tx | ↔ (bidirectional) | 3 |
| GND | ↔ (bidirectional) | 5 |
| ↕︎ (tie) | 7 8 |