All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Fanuc 0i/30i/31i/32i/35i Series. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Supported Series: Fanuc 0i/30i/31i/32i/35i Series

Website: http://www.fanucfa.com/welcome_worldwide/

HMI Settings

Parameters Recommended Options Notes
PLC type Fanuc 0i/30i/31i/32i/35i Series
PLC I/F RS232
Baud rate 19200
Data bits 8
Parity Even
Stop bits 1
PLC sta. no. 0
On-line simulation YES

PLC Setting

Reader/Puncher interface (2ch.) is used for touch panel interface.

External touch panel interface, S/N: A02B-0320-J685, for Power Mate Series.

Device Address

Bit/Word Device type Format Range Memo
BXDDDDo0 ~ 11277
BYDDDDo0 ~ 11277
BKDDDo0 ~ 9997
BEDDDDo0 ~ 99997
BD_BitDDDDo0 ~ 99997
BR_BitDDDDo0 ~ 94997
WTDDDD0 ~ 9499Must be a multiple of 2
WCDDDD0 ~ 5199Must be a multiple of 4
WD_ByteDDDD0 ~ 9999
WR_ByteDDDD0 ~ 9499
WDDDDD0 ~ 9999Must be a multiple of 2
WRDDDD0 ~ 9499Must be a multiple of 2

Wiring Diagram

NOTE: The serial port pin assignments may vary between HMI models.

RS-232

The following is the view from the soldering point of a connector.

20-pin communication port connector for Fanuc 0i/30i/31i/32i/35i Series, showing two rows of numbered pin positions 1–9 and 11–20.
HMI Direction PLC
Pin assignments RS232
20P JD36B or JD54
Female
Rx ↔ (bidirectional) 11
Tx ↔ (bidirectional) 1
GND ↔ (bidirectional) 8(JD36)/4(JD54)
↕︎ (tie) 15
5
↕︎ (tie) 3
7
13