Introduction

All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with ABB EtherNet/IP (Implicit Messaging). Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Supported Series: ABB EtherNet/IP (Implicit Messaging)

HMI Setting

ParametersRecommendedOptionsNotes
PLC typeABB EtherNet/IP (Implicit Messaging)
PLC I/FEthernet
Port no.44818
Assembly instanceInput: 101
Output: 111
Input: 101~106
Output: 111~116
ModeAnybus Adapter (IRC5-DSQC669)Anybus Adapter (IRC5-DSQC669)
EIP Adapter (IRC5-DSQC10XX)
Online simulatorYES

Device Address

Bit/WordDevice typeFormatRange
BInput_BitDDDdd0 ~ 51215
BOutput_BitDDDdd0 ~ 51215
BInputDDD0 ~ 512
BOutputDDD0 ~ 512

Application Example

ABB robot’s parameter settings are very flexible; almost all of its functions can be performed through communication with HMI. The below is a list showing how ABB robot’s parameters map to HMI function. Contents in this mapping list are all user-defined. This list shows that HMI can directly control the robot to accomplish miscellaneous tasks, while at the same time allowing users to monitor robot status.

Sample Robot I/O List

ParametersInput AddressOutput AddressFormatBitHMI Function
Start At Main0Bool1Start Button
Servo On1Bool1Start Button
Product to be Produced2–17Word16Product Selection Button (1~16)
Reserved Variable 118–33Word16Reserved Variable
Coordinate Offset 134–65Float32Offset (e.g. -3.734mm)
Task Executing0Bool1Status: In Operation
Auto On1Bool1Status: In Auto. Mode
Production in Progress #1~#162~17Word16Status: Product No. in Production
Robot’s Reserved Variable 118~33Word16Reserved Variable 1 (e.g. Production is OK/NG)
Robot’s Reserved Variable 234~49Word16Reserved Variable 2 (e.g. Extend the time for 217 seconds)

Wiring Diagram

The diagram below shows the Ethernet cable wiring.

Ethernet straight-through cable wiring diagram showing eight color-coded wire pairs connecting pin-for-pin from W/Orange on pin 1 to Brown on pin 8.