Introduction

All Maple Systems HMI Panels programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Control Technology 2500 Series. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Supported Series: CTI 2500 Series PLCs (Classic and Compact): C100, C200, C300 and C400

Website: www.controltechnology.com

HMI Setting

ParametersRecommendedOptionsNotes
PLC typeControl Technology 2500 SeriesNITP protocol
PLC I/FRS232RS232, RS485 4W
Baud rate1920019200
Data bits77
ParityOddOdd
Stop bits11
PLC sta. no.0Does not apply

Device Address

Bit/WordDevice typeFormatRangeMemo
BCRDDDDD1 ~ 65535Internal Relay
BXDDDDD1 ~ 65535Discrete Input Coils
BYDDDDD1 ~ 65535Discrete Output Coils
BV_BitDDDDDdd101 ~ 6553616User Data Register Bits
WVDDDDD1 ~ 65535User Data Registers
DWVDDDDDD1 ~ 65536User Data Registers (32bit)
WSTWDDDDD1 ~ 65535Status Word Registers
WTCPDDDDD1 ~ 65535Timer/Counter Preset Values
WTCCDDDDD1 ~ 65535Timer/Counter Current Values
WWXDDDDD1 ~ 65535Word Discrete Inputs
WWYDDDDD1 ~ 65535Word Discrete Outputs

NOTE: Because VD (double word) will do high and low word conversion, avoid mixing V and VD when performing data transfer and macro.

Wiring Diagram

NOTE: The serial port pin assignments may vary between HMI models.

Diagram 1: RS-232

HMIDirectionPLC
Pin assignmentsRS232
9P D-Sub
Male
Rx↔ (bidirectional)3 TX
Tx↔ (bidirectional)2 RX
GND↔ (bidirectional)5 GND

Diagram 2: RS-485 4W

HMIDirectionPLC
Pin assignmentsRS485 4W 6P
Mini-DIN
Male
Rx-↔ (bidirectional)8 Tx-
RX+↔ (bidirectional)3 Tx+
Tx-↔ (bidirectional)2 Rx-
Tx+↔ (bidirectional)9 Rx+
GND↔ (bidirectional)5 GND