Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Bosch Rexroth. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
HMI Setting
| Parameters | Recommended | Options |
|---|---|---|
| PLC type | Bosch Rexroth | |
| PLC I/F | RS232 | |
| Baud rate | 115200 | |
| Data bits | 8 | |
| Parity | None | |
| Stop bits | 1 | |
| PLC sta. no. | 1 |
Support Device Type
| Data type | EasyBuilder data format | Memo |
|---|---|---|
| Bool | bit | |
| Byte | 16-bit BCD, Hex, Binary, Unsigned | 8-bit |
| SInt | 16-bit BCD, Hex, Binary, Signed | 8-bit |
| USInt | 16-bit BCD, Hex, Binary, Unsigned | 8-bit |
| Word | 16-bit BCD, Hex, Binary, Unsigned | 16-bit |
| Int | 16-bit BCD, Hex, Binary, Signed | 16-bit |
| UInt | 16-bit BCD, Hex, Binary, Unsigned | 16-bit |
| DWord | 32-bit BCD, Hex, Binary, Unsigned | 32-bit |
| DInt | 32-bit BCD, Hex, Binary, Signed | 32-bit |
| Real | 32-bit Float | 32-bit |
| UDInt | 32-bit BCD, Hex, Binary, Unsigned | 32-bit |
-
Import Tags
Launch IndraWorks PLC software, click [Global_Variables], and edit the project.
Struct can be edited in [Data types] tab, and Global_varaibles can be edited in [Resources] tab.
-
Export Tags
After editing the project, click [Project] -> [Export] to export the tags.
You may select all, a part of, or a single file to export. Click [OK], enter the file name and designate the directory to store the file.
-
Import Tags into EBPro
Launch EBPro (EasyBuilder), select Bosch Rexroth driver, and import the address tags. The illegal addresses will be eliminated, and displayed in the [Error status] field. Click [OK] to leave.
“Import successfully” message will be displayed when successfully import the address tags.
Wiring Diagram
NOTE: The serial port pin assignments may vary between HMI models.
RS-232
| HMI | Direction | PLC |
|---|---|---|
| Pin assignments | RS232 Terminal | |
| Rx | ↔ (bidirectional) | 2 TXD |
| Tx | ↔ (bidirectional) | 3 RXD |
| GND | ↔ (bidirectional) | 5 GND |