The leader in industrial automation and control solutions

Introduction

All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with NMEA 0183. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Supported Series: NMEA 0183 Interface Standard

HMI Settings

ParametersRecommendedOptionsNotes
PLC typeNMEA 0183
PLC I/FRS232
Baud rate48004800 ~ 115200
Data bits87, 8
ParityNoneNone, Even, Odd
Stop bits11, 2

NMEA Sentences

Supported SentencesSupported SentencesSupported SentencesSupported SentencesSupported SentencesSupported Sentences
AAMACKADSAKDALAALM
ALRAPBBECBODBWCBWR
BWWCOPCURDBTDCRDDC
DORDPTDSCDTMETLEVE
FIRFSIGBSGGAGLCGLL
GMPGNSGRSGSAGSTGSV
HDGHMRHMSHSCHSSHTC
HTDLCDMDAMLAMSKMSS
MTWMWDMWVNAKNRMOSD
PRCRMARMBRMCRORROT
RPMRSARSDRSTSFISID
STNTHSTLLTRDTTMTUT
TXTUIDVBWVDRVERVHW
VLWVPWVTGWATWCVWNC
WPLXTEXTRZDAZDLZFO
ZTG

Wiring Diagram

NOTE: The serial port pin assignments may vary between HMI models.

RS-232

HMIDirectionPLC
Pin assignmentsRS232
9P D-Sub
Male
Rx↔ (bidirectional)SD
Tx↔ (bidirectional)RD
GND↔ (bidirectional)GND