Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Barcode Scanner CDC/POS Mode (USB). Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
HMI Settings
| Parameters | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | Barcode Scanner CDC/POS Mode (USB) | ||
| PLC I/F | USB | ||
| Mode | CDC | CDC, POS |
Device Address
| Bit/Word | Device type | Format | Range | Memo |
|---|---|---|---|---|
| B | flag | D | 0 | automatic return |
| W | data | DDDD | 0 ~ 1999 | |
| W | state | D | 0 | *Note |
| W | len | D | 0 |
Note: State Values
| State Value | Device State |
|---|---|
| state 0 | Device removed or mode set incorrectly |
| state 1 | Device connection is successful. |