Compare PLC Products
|
Filters |
Modular CPU Relay PLC-ES0806R $320
|
Modular CPU PLC-ES0808P $320
|
36-channel Micro PLC Relay PLC-FB1616R0202 $320
|
|---|---|---|---|
| Loading product data… | |||
| PLC-ES0806R | PLC-ES0808P | PLC-FB1616R0202 | |
| USB | USB 2.0 (Mini-B) x 1 | USB 2.0 (Mini-B) x 1 | USB 2.0 (Mini-B) x 1 |
| Ethernet/LAN | 10/100 Base-T x 1 | 10/100 Base-T x 1 | 10/100 Base-T x 1 |
| SD Card Slot | N/A | N/A | N/A |
| Serial | 1 x RS232, 1x RS422/RS485 | 1 x RS232, 1x RS422/RS485 | 1 x RS232, 1x RS422/RS485 |
| PLC-ES0806R | PLC-ES0808P | PLC-FB1616R0202 | |
| Program Languages | Ladder (LD), Instruction List (I/L), Function Block (FB), Sequential Function Chart (SFC) | Ladder (LD), Instruction List (I/L), Function Block (FB), Sequential Function Chart (SFC) | Ladder (LD), Instruction List (I/L), Function Block (FB), Sequential Function Chart (SFC) |
| Power Consumption | 12 W, 12/24 VDC, 0.5 A at 24 VDC | 12 W, 12/24 VDC, 0.5 A at 24 VDC | 9.60 W, 24 VDC, 0.40 A at 24 VDC |
| High-Speed Counter (HSC) | Yes | Yes | Yes |
| Positioning | No | Yes | No |
| Number of Channels | 14 Total: 8 Digital Inputs, 6 Digital Relay Outputs | 16 Total: 8 Digital Inputs, 8 Digital Outputs | 36 Total: 16 Digital Inputs, 16 Digital Relay Outputs, 2 Analog Inputs, 2 Analog Outputs |
| Program Memory | 10K STEP | 10K STEP | 10K STEP |
| Execution Speed | 300ns/STEP | 300ns/STEP | 300ns/STEP |
| Number of IO Points | 384 (maximum) | 384 (maximum) | 36 |
| PLC-ES0806R | PLC-ES0808P | PLC-FB1616R0202 | |
| Digital Input Type | TR Sink/Source | TR Sink/Source | TR Sink/Source |
| Digital Output Type | Relay | TR Source | Relay |
| Rated Digital Input Voltage | 24 VDC (12 or 24 VDC is used for HSC) | 24 VDC (12 or 24 VDC is used for HSC) | 24 VDC (12 or 24 VDC is used for HSC) |
| Rated Digital Output Voltage | 24 VDC, 220 VAC | 12/24 VDC | 24 VDC, 220 VAC |
| Rated Digital Output Current | 1 point = 2 A, 1 COM = 5 A | 1 point = 0.2 A, 1 COM = 2 A | 1 point = 2 A, 1 COM = 5 A |
| Digital Output Insulation Method | Relay | Photocoupler | Relay |
| Digital Input Insulation Method | Photocoupler | Photocoupler | Photocoupler |
| Rated Digital Input Current | 4 mA | 4 mA | 4 mA |
| PLC-ES0806R | PLC-ES0808P | PLC-FB1616R0202 | |
| Input Type | N/A | N/A | Voltage: 0-10 V, 1-10V, 0-5 V, 1-5 V Current: 0–20 mA, 4-20 mA |
| Output Type | N/A | N/A | Voltage: 0–10 V (Load resistance > 1 kΩ) Current: 4–20 mA (Load resistance < 600 Ω) |
| PLC-ES0806R | PLC-ES0808P | PLC-FB1616R0202 | |
| Dimensions WxHxD | 30 x 91 x 64 mm (1.2 x 3.6 x 2.5 in) | 30 x 91 x 64 mm (1.2 x 3.6 x 2.5 in) | 93 x 135 x 75 mm (3.7 x 5.3 x 3.0 in) |
| Weight | 165 g (0.36 lb) | 155 g (0.34 lb) | 415g (0.91lb) |
| Shock | 15G | 15G | 15G |
| Vibration | 0.5G Continuous, 1G Discontinuous | 0.5G Continuous, 1G Discontinuous | 0.5G Continuous, 1G Discontinuous |
| Square Wave Impulse Noise | ±2 kV | ±2 kV | ±2 kV |
| ESD Immunity | ±4 kV – Contact Discharges, ±8 kV – Air Discharges | ±4 kV – Contact Discharges, ±8 kV – Air Discharges | ±4 kV – Contact Discharges, ±8 kV – Air Discharges |
| Radiated Electromagnetic Immunity | 80–1000 MHz, 10 V/m | 80–1000 MHz, 10 V/m | 80–1000 MHz, 10 V/m |
| Surge Transient Immunity | 2 kV – CPU, Power; 2 kV – Digital I/O (VAC); 1 kV – Digital I/O (VDC); 1 kV – Communication | 2 kV – CPU, Power; 2 kV – Digital I/O (VAC); 1 kV – Digital I/O (VDC); 1 kV – Communication | 2 kV – CPU & Power, 2 kV – Digital I/O (VAC), 1 kV – Digital I/O (VDC), 1 kV – Communication |
| PLC-ES0806R | PLC-ES0808P | PLC-FB1616R0202 | |
| Operating Temperature | 10 – 60 °C (14 – 140 °F) | 10 – 60 °C (14 – 140 °F) | 10 – 55 °C (14 – 131 °F) |
| Storage Temperature | 25 – 80 °C (-13 – 176 °F) | 25 – 80 °C (-13 – 176 °F) | 25 – 80 °C (-13 – 176 °F) |
| Operating/Storage Relative Humidity | 5 – 95% Non-condensing | 5 – 95% Non-condensing | 5 – 95% Non-condensing |
| PLC-ES0806R | PLC-ES0808P | PLC-FB1616R0202 | |
| CE | Yes | Yes | Yes |
| UL | cULus Listed | cULus Listed | cULus Listed |
| RoHS | Yes | Yes | Yes |
