All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with an Omron Ethernet (FINS/TCP). Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

Supported Series: Non OMRON PLC . (Ethernet FINS)

HMI Settings

ParametersRecommendedOptionsNotes
PLC typeOMRON Ethernet (FINS/TCP)
PLC I/FEthernet
Port no.9600
PLC sta. no.0

PLC Setting

ParameterValue
Communication modeEthernet (FINS/TCP) protocol

Device Address

Bit/WordDevice typeFormatRangeMemo
BCIO_BitDDDDDdd0 ~ 3276715Channel I/O (CIO)
BW_BitDDDDDdd0 ~ 3276715Work Area (WR)
BH_BitDDDDDdd0 ~ 3276715Holding Area (HR)
BA_BitDDDDDdd0 ~ 3276715Auxiliary Relay (AR) (Read Only)
BD_BitDDDDDdd0 ~ 3276715Data Memory (DM)
BT_BitDDDDDdd0 ~ 3276715Timer (TIM)
BC_BitDDDDDdd0 ~ 3276715Counter (CNT)
BC_FlagDDDD0 ~ 4095
BT_FlagDDDD0 ~ 4095
BEM0_Bit ~ EM18_BitDDDDDdd0 ~ 3276715Extend Memory Bit
WCIODDDDD0 ~ 32767Channel I/O (CIO)
WWDDDDD0 ~ 32767Work Area (WR)
WHDDDDD0 ~ 32767Holding Area (HR)
WADDDDD0 ~ 32767Auxiliary Relay (AR) (Read Only)
WCDDDDD0 ~ 32767Counter (CNT)
WTDDDDD0 ~ 32767Timer (TIM)
WDDDDDD0 ~ 32767Data Memory (DM)
WEM0 ~ EM18DDDDD0 ~ 32767Extend Memory

Wiring Diagram

The diagram below shows the Ethernet cable wiring.

Ethernet cable wiring diagram for connecting Maple Systems HMI to OMRON PLC using FINS/TCP protocol.