Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Motrona BY-340. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
Supported Series: motrona BY-340
Website: motrona.net
HMI Settings
| Parameters | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | motrona BY-340 | ||
| PLC I/F | RS232 | ||
| Baud rate | 9600 | 1200 ~ 38400 | |
| Data bits | 7 | 7, 8 | |
| Parity | Even | Even, Odd, None | |
| Stop bits | 1 | 1, 2 | |
| PLC sta. no. | 11 | 11 ~ 99 |
Device Address
| Bit/Word | Device type | Format | Range | Note |
|---|---|---|---|---|
| B | Reset | D | 0 | |
| B | Trim- | D | 0 | |
| B | Trim+ | D | 0 | |
| B | Activate Data | D | 0 | |
| B | Integrator off | D | 0 | |
| B | Store EEProm | D | 0 | |
| B | Scroll Display | D | 0 | |
| B | Keyboard Disable | D | 0 | |
| B | Clear Min. & Max. | D | 0 | |
| B | Read front F1 | D | 0 | |
| B | Stop Slave | D | 0 | |
| B | Index Slave | D | 0 | |
| B | Index Master | D | 0 | |
| B | Reset Ex | D | 0 | |
| B | Trim- Ex | D | 0 | |
| B | Trim+ Ex | D | 0 | |
| B | Integrator off Ex | D | 0 | |
| B | Store EEProm Ex | D | 0 | |
| B | Scroll Display Ex | D | 0 | |
| B | Keyboard Disable Ex | D | 0 | |
| B | Clear Min. & Max. Ex | D | 0 | |
| B | Read front F1 Ex | D | 0 | |
| B | Stop Slave Ex | D | 0 | |
| B | Index Slave Ex | D | 0 | |
| B | Index Master Ex | D | 0 | |
| B | Output Unit ready | D | 0 | |
| B | Output Led 1 | D | 0 | |
| B | Output Led 2 | D | 0 | |
| B | Output Status 4 | D | 0 | |
| B | Output max. Frequency | D | 0 | |
| B | Output max. Correction | D | 0 | |
| B | Output Alert 2 | D | 0 | |
| B | Output Alert 1 | D | 0 | |
| DW | Factor 1 | D | 0 | |
| DW | Factor 2 | D | 0 | |
| W | Operational Mode | D | 0 | |
| W | Trim Time | D | 0 | |
| W | Integration Time | D | 0 | |
| W | Correction Divider | D | 0 | |
| DW | Factor 1 Scaling | D | 0 | |
| DW | Factor 1 Minimum | D | 0 | |
| DW | Factor 1 Maximum | D | 0 | |
| W | Sampling Time | D | 0 | |
| W | Wait Time | D | 0 | |
| DW | Max. Master Frequency | D | 0 | |
| W | Ramp Time | D | 0 | |
| W | Stop-Ramp Time | D | 0 | |
| W | Alert 1 | D | 0 | |
| W | Alert 2 | D | 0 | |
| DW | Phase Offset | D | 0 | |
| DW | Slave Pulses Index | D | 0 | |
| W | Phase Adjust | D | 0 | |
| W | Master Index Divider | D | 0 | |
| W | Index Window | D | 0 | |
| W | Max. Index Correction | D | 0 | |
| W | M Encoder Properties | D | 0 | |
| W | M Edge Counting | D | 0 | |
| W | M Counting Direction | D | 0 | |
| W | M Speed Display Factor | D | 0 | |
| W | M Speed Display Divider | D | 0 | |
| W | M Speed Display Dec.Point | D | 0 | |
| W | S Encoder Properties | D | 0 | |
| W | S Edge Counting | D | 0 | |
| W | S Counting Direction | D | 0 | |
| W | Analogue Format | D | 0 | |
| W | Offset Correction | D | 0 | |
| W | Gain Correction | D | 0 | |
| W | Max. Correction | D | 0 | |
| W | Offset Total | D | 0 | |
| W | Gain Total | D | 0 | |
| W | Key Up Function | D | 0 | |
| W | Key Down Function | D | 0 | |
| W | Key Enter Function | D | 0 | |
| W | Input 1 Configuration | D | 0 | |
| W | Input 1 Function | D | 0 | |
| W | Input 2 Configuration | D | 0 | |
| W | Input 2 Function | D | 0 | |
| W | Input 3 Configuration | D | 0 | |
| W | Input 3 Function | D | 0 | |
| W | Input 4 Configuration | D | 0 | |
| W | Input 4 Function | D | 0 | |
| W | Unit Number | D | 0 | |
| W | Serial Baud Rate | D | 0 | |
| W | Serial Format | D | 0 | |
| W | Input Filter | D | 0 | |
| W | Trigger Threshold 1 | D | 0 | |
| W | Trigger Threshold 2 | D | 0 | |
| W | Brightness | D | 0 | |
| W | Frequency Control | D | 0 | |
| W | Factor Store Config | D | 0 | |
| W | Display Time | D | 0 | |
| W | Default Display | D | 0 | |
| DW | Protect Group F01 | D | 0 | |
| DW | Protect Group F02 | D | 0 | |
| DW | Protect Group F03 | D | 0 | |
| DW | Protect Group F04 | D | 0 | |
| DW | Protect Group F05 | D | 0 | |
| DW | Protect Group F06 | D | 0 | |
| DW | Protect Group F07 | D | 0 | |
| DW | Protect Group F08 | D | 0 | |
| DW | Protect Group F09 | D | 0 | |
| DW | test value | D | 0 | |
| DW | Differential_Counter | D | 0 | |
| DW | Diff_Counter_nodiv | D | 0 | |
| DW | ana_voltage | D | 0 | |
| DW | new_Counter_Master | D | 0 | |
| DW | new_Counter_Slave | D | 0 | |
| DW | frequency_a/10 | D | 0 | |
| DW | scal_F1 | D | 0 | |
| DW | Index_Buffer_Master | D | 0 | |
| DW | Index_Buffer_Slave | D | 0 | |
| DW | Index_Status | D | 0 | |
| DW | Counter_Master | D | 0 | |
| DW | Counter_Slave | D | 0 | |
| DW | Master_Index_Counter | D | 0 | |
| DW | Phase_Counter_Slave | D | 0 | |
| DW | Phase_Corr_Buffer | D | 0 | |
| DW | Trim_Phase | D | 0 | |
| DW | Index_Pulses_Master | D | 0 | |
| DW | Index_Pulses_Slave | D | 0 | |
| DW | Loop_time | D | 0 | |
| DW | Test_Variable | D | 0 | |
| DW | Base_Ram | D | 0 |
Wiring Diagram
NOTE: The serial port pin assignments may vary between HMI models.
RS-232
| HMI | Direction | PLC |
|---|---|---|
| Pin assignments | RS232 32P terminal | |
| Rx | ↔ (bidirectional) | 30 TXD |
| Tx | ↔ (bidirectional) | 14 RXD |
| GND | ↔ (bidirectional) | 31 GND |