Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Motrona CT-150. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
Supported Series: motrona CT-150
Website: http://motrona.net/index.html
HMI Setting
| Parameters | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | motrona CT-150 | ||
| PLC I/F | RS232 | RS232/RS485 | |
| Baud rate | 9600 | 1200 ~ 38400 | |
| Data bits | 7 | 7, 8 | |
| Parity | Even | Even, Odd, None | |
| Stop bits | 1 | 1, 2 | |
| PLC sta. no. | 11 | 11 ~ 99 | The station number must not contain 0. |
Device Address
| Bit/Word | Device type | Format | Range |
|---|---|---|---|
| W | An |
D | 4 ~ 8 |
| W | Bn |
D | 1 ~ 9 |
| W | Cn |
DD | 0 ~ 99 |
| W | An_32Bit |
D | 4 ~ 8 |
| W | Bn_32Bit |
D | 1 ~ 9 |
| W | Cn_32Bit |
DD | 0 ~ 99 |
| W | ERR_CNT |
D | 0 |
| W | LV_VAL |
D | 0 |
| W | PRTMARK_ERR |
D | 0 |
| W | BAT_CNT |
D | 0 |
| W | WASTE_CNT |
D | 0 |
| W | LINE_SPD |
D | 0 |
| W | ACT_CUT_LEN |
D | 0 |
| W | ACT_CUT_ERR_M |
D | 0 |
| W | ACT_CUT_ERR_L |
D | 0 |
Wiring Diagram
NOTE: The serial port pin assignments may vary between HMI models.
RS-232
| HMI | Direction | PLC |
|---|---|---|
| Pin assignments | RS232 9P D-Sub Female |
|
| Rx | ↔ (bidirectional) | 3 TXD |
| Tx | ↔ (bidirectional) | 2 RXD |
| GND | ↔ (bidirectional) | 5 GND |