Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Fanuc 0i/30i/31i/32i/35i Series. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
Supported Series: Fanuc 0i/30i/31i/32i/35i Series
HMI Settings
| Parameters | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | Fanuc 0i/30i/31i/32i/35i Series | ||
| PLC I/F | RS232 | ||
| Baud rate | 19200 | ||
| Data bits | 8 | ||
| Parity | Even | ||
| Stop bits | 1 | ||
| PLC sta. no. | 0 | ||
| On-line simulation | YES |
PLC Setting
Reader/Puncher interface (2ch.) is used for touch panel interface.
External touch panel interface, S/N: A02B-0320-J685, for Power Mate Series.
Device Address
| Bit/Word | Device type | Format | Range | Memo |
|---|---|---|---|---|
| B | X | DDDDo | 0 ~ 11277 | |
| B | Y | DDDDo | 0 ~ 11277 | |
| B | K | DDDo | 0 ~ 9997 | |
| B | E | DDDDo | 0 ~ 99997 | |
| B | D_Bit | DDDDo | 0 ~ 99997 | |
| B | R_Bit | DDDDo | 0 ~ 94997 | |
| W | T | DDDD | 0 ~ 9499 | Must be a multiple of 2 |
| W | C | DDDD | 0 ~ 5199 | Must be a multiple of 4 |
| W | D_Byte | DDDD | 0 ~ 9999 | |
| W | R_Byte | DDDD | 0 ~ 9499 | |
| W | D | DDDD | 0 ~ 9999 | Must be a multiple of 2 |
| W | R | DDDD | 0 ~ 9499 | Must be a multiple of 2 |
Wiring Diagram
NOTE: The serial port pin assignments may vary between HMI models.
RS-232
The following is the view from the soldering point of a connector.

| HMI | Direction | PLC |
|---|---|---|
| Pin assignments | RS232 20P JD36B or JD54 Female |
|
| Rx | ↔ (bidirectional) | 11 |
| Tx | ↔ (bidirectional) | 1 |
| GND | ↔ (bidirectional) | 8(JD36)/4(JD54) |
| ↕︎ (tie) | 15 5 |
|
| ↕︎ (tie) | 3 7 13 |