Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with CoDeSys V2 (Absolute Addressing) (Ethernet). Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
HMI Setting
| Parameters | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | CODESYS V2 (Absolute Addressing) (Ethernet) | ||
| PLC I/F | Ethernet | ||
| Port no. | 1200 | ||
| PLC sta. no. | No need to set station no. |
Device Address
| Bit/Word | Device | Format | Range | Memo |
|---|---|---|---|---|
| B | IX | DDDDDdd | 0 ~ 6553515 | |
| B | QX | DDDDDdd | 0 ~ 6553515 | |
| B | MX | DDDDDdd | 0 ~ 6553515 | |
| W | IW | OOOOOO | 0 ~ 65535 | |
| W | QW | DDDDD | 0 ~ 65535 | |
| W | MW | DDDDD | 0 ~ 65535 | |
| W | ID | DDDDD | 0 ~ 65535 | |
| W | QD | DDDDD | 0 ~ 65535 | |
| W | MD | DDDDD | 0 ~ 65535 |
Wiring Diagram
The diagram below shows the Ethernet cable wiring.