Introduction
All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with Lenze 9300/8200 Series and EPL10200. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
Supported Series: PLC Model No.: 9300/8200 series, and EPL10200
Protocol: RS485 (LECOM B) via Lenze 2102IB fieldbus module
Website: http://www.lenze.de
HMI Settings
| Parameters | Recommended | Options |
|---|---|---|
| PLC type | Lenze | |
| PLC I/F | RS232 | |
| Baud rate | 9600 | 9600, 19200 |
| Data bits | 7 | 7, 8 |
| Parity | None | Even, Odd, None |
| Stop bits | 1 | 1, 2 |
| PLC sta. no. | 1 | 0–255 |
PLC Settings
Communication mode: Same as the HMI setting.
Device Address
| Bit/Word | Device Type | Format | Range | Notes |
|---|---|---|---|---|
| B | CNB |
DDDDdd |
0 ~ 999915 | Subcode not supported. Can only read/write CNI Word Type. |
| B | CB |
DDDDddxx |
0 ~ 81920015 | Subcode supported. Can only read/write CI Word Type. |
| W | CI |
DDDDdd |
0 ~ 819200 | Subcode supported. Integer. |
| W | CD |
DDDDdd |
0 ~ 819200 | Subcode supported. DWord. |
| W | CF |
DDDDdd |
0 ~ 819200 | Subcode supported. DWord (float point). |
| W | CNI |
DDDD |
0 ~ 9999 | Subcode not supported. Integer. |
| W | CND |
DDDD |
0 ~ 9999 | Subcode not supported. DWord. |
| W | CNF |
DDDD |
0 ~ 9999 | Subcode not supported. DWord (float point). |
Wiring Diagram
RS-485 2W
NOTE: The serial port pin assignments may vary between HMI models.
| HMI | Direction | PLC |
|---|---|---|
| Pin assignments | Lenze 2102IB LECOM-B RS485 plug-in terminal |
|
| Data− | ↔ (bidirectional) | 72 T/R (A) |
| Data+ | ↔ (bidirectional) | 71 T/R (B) |
| GND | — (passive) |