The leader in industrial automation and control solutions

Introduction

All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with LoXin Controller. Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.

This page serves as a reference for setting up communications between a Maple Systems HMI/cMT unit and a LoXin Controller. It details the protocol settings, device addressing, and physical wiring requirements.

Website: http://www.loxin-china.com

HMI Settings

ParametersRecommendedOptionsNotes
PLC typeLoXin
PLC I/FRS-485 2W
Baud rate9600
Data bits8
ParityOdd
Stop bits1
PLC sta. no.0

Device Address

Bit/WordDevice typeFormatRangeMemo
WBattery_UnitD0
WInsulator_UnitD0
WSwitch_UnitD0

Wiring Diagram

NOTE: The serial port pin assignments may vary between HMI models.

RS-485 2W

HMIDirectionPLC
Pin assignmentsRS485 2W
9D-Sub Male
Data-↔ (bidirectional)D-
Data+↔ (bidirectional)D+
GND↔ (bidirectional)GND