All Maple Systems HMIs programmed with EBPro (EasyBuilder Pro), including every cMT X Series and cMT Series model, are compatible with a Mitsubishi Q00UJ/QnU/QnUD/QnUDH/QnUDEH/L (mini USB). Configure your Controller and HMI/cMT with the following parameters to establish reliable communication.
Supported Series: Mitsubishi Q00UJ, Q00U, Q01U, Q02U, Q03UDE, Q03UD, Q04UDEH, Q04UDH, Q06UDEH, Q06UDH, Q10UDEH, Q10UDH, Q13UDEH, Q13UDH, Q20UDEH, Q20UDH, Q26UDEH, Q26UDH, L02, L26-BT USB Port.
HMI Setting
| Parameters | Recommended | Options | Notes |
|---|---|---|---|
| PLC type | Mitsubishi Q00UJ/QnU/QnUD/QnUDH/QnUDEH/L (mini USB) | ||
| PLC I/F | USB | CPU port direct connect | |
| Online Simulator | NO | ||
| Pass-Through | NO |
Device Address
| Bit/Word | Device type | Format | Range | Memo |
|---|---|---|---|---|
| B | SM | DDDD | 0 ~ 2047 | |
| B | X | HHHH | 0 ~ 1fff | Input Relay |
| B | Y | HHHH | 0 ~ 1fff | Output Relay |
| B | M | DDDDD | 0 ~ 61439 | Internal Relay |
| B | L | DDDD | 0 ~ 8191 | Latch Relay |
| B | F | DDDD | 0 ~ 2047 | Annunciator |
| B | V | DDDD | 0 ~ 2047 | Edge Relay |
| B | B | HHHH | 0 ~ 1fff | Link Relay |
| B | SB | HHH | 0 ~ 7ff | Special Link Relay |
| B | D_Bit | DDDDDDDh | 0 ~ 4212735f | |
| B | ZR_Bit | HHHHh | 0 ~ fffff | |
| B | ZR_Dec_Bit | DDDDDh | 0 ~ 65535f | |
| W | SD | DDDD | 0 ~ 2047 | |
| W | D | DDDDDDD | 0 ~ 4212735 | Data Register |
| W | W | HHHH | 0 ~ 1fff | Link Register |
| W | SW | HHH | 0 ~ 7ff | Special Link Register |
| W | Z | DD | 0 ~ 19 | Index Register |
| W | R | FFDDDDD | 0 ~ 132767 | File Register (FF:File No. 0~31) (DDDDD:0~32767) |
| W | ZR | HHHH | 0 ~ ffff | File Register |
| W | ZR_decimal_addr | DDDDD | 0 ~ 65535 | |
| W | C | DDDD | 0 ~ 1023 | Counter Current Value |
| W | T | DDDD | 0 ~ 2047 | Timer Current Value |