How do I update the Firmware on a cMT-iV5 and/or a cMT-iV6?

These products are discontinued. Contact [email protected] for upgrade information. The Utility Manager application that comes bundled and installed with EBPro, features a Firmware upgrade utility for the cMT-iV5 and iV6. The Utility Manager application is located in the root of the EBPro installation directory. By default, it is installed in C:Maple SystemsEBProUtilityManagerEx.exe. You will need…

When I create a new Meter Display object and use a REAL or DINT data type/tag from a PLC, I can not add negative values in the limits.

When creating a New Meter Display Object for a cMT Series HMI, you may not be able to assign a negative value for the minimum or maximum values when using REAL, DINT, or INT signed data types. Solution: First, select a Local Word (LW) register for the Read Address in the Meter Display Object Properties…

Why am I experiencing a compile error in Window 8: “Unsupported system tag LB-9036: SD card free space insufficiency alarm (when ON)”?

When compiling a project that was originally created in an older version of EBPro, this error will occur if the model that was selected when the project was originally created does not support SD cards. This is due to a change that was implemented in EBPro: Version 6.05.01. With this change, if the originally selected…