Converting from a RMI5001 to a cMT-FHDX-820
Converting from your RMI5001 is quick and easy, giving you several key hardware and software upgrades along the way.
Converting from your RMI5001 is quick and easy, giving you several key hardware and software upgrades along the way.
If an HMI will not connect to the EasyAccess 2.0 server and you get an Error Code 207 (Timeout SSL Connect), it is possible that the router or cellular modem through which the HMI is connecting to the internet may need to have the MTU (Maximum Transmission Units) setting increased. Some routers and modems have…
Read More I get Error Code 207 when attempting to connect my HMI to EasyAccess 2.0
The EasyAccess2.0 Domain web page has recently been redesigned. Upon navigating to account.ihmi.net/domain, the website redirects to the weincloud.net/account/login web page. You may notice a new user interface. You can use your existing credentials to log into the Weintek Cloud Service login page. From the new Weincloud Management web page, you can manage your Domain, Users,…
Read More Why does my EasyAccess2.0 domain login web page look different?
To address multiple devices, using the Modbus TCP/IP Gateway function: 1. Select the table for the mapped device. 2. Click the “Settings…” button at the bottom of the Address Mapping Table window. 3. Specify the mapped device address in the Table Settings window. Follow Technical Note 5099 “Using the Modbus Gateway” for step-by-step instructions.
Read More How do I address multiple devices using the Modbus TCP/IP Gateway function?
The Standard Series HMIs now support VNC (EBPro v6.03.02.257 or later). Since the B-Series do not have the VNC tab in the System Settings window to enable VNC, it needs to be done with System Bits and Words. LW-9530 to LW-9533 are used to store the VNC server password on the HMI in ASCII format.…
When connecting to your cMT–X Series through EasyWeb, you are able to export data logs, event logs, and operation logs as well as make backups of the database directly to your PC. To connect via EasyWeb, enter the IP address of the cMT-X Series in your browser’s URL (the default System password is: 111111). Click on the “Data” tab in the menu on the left side of EasyWeb and then…
Since the Settings window for the cMT-FHDX does not have an option to enable the VNC server, you can do it with a System Bit in the HMI. LB-12092 is used to enable/disable the VNC server. LB-12093 is used to select single-connection or multi-connection (OFF=single; ON=multi). You could place a Toggle Switch on a window…
With EasyAccess 2.0, only live data (no graphics) is communicated across the network between the local HMI and the remote device, preserving bandwidth and enabling faster data transfer.
We have both Advanced HMIs and High-Performance cMT/HMIs models with built-in Wi-Fi functionality.
Read More Is Wi-Fi built into Maple Systems High-Performance cMT or Advanced HMIs?
OPC UA is a communication protocol supported by many SCADA, MES, and ERP software providers. OPC UA uses a Client/Server architecture. This protocol has built-in security with signed and encrypted data transfer using state-of-the-art encryption algorithms. Data is organized into objects, making it easy to access and quickly understand what the data represents, and how…
Add a headless HMI to your control system, using one of the Ethernet ports to connect it to the corporate LAN. The headless HMI will collect data from the plant floor, translate it to Modbus and send it to the office computer.
Transmission Control Protocol/Internet Protocol (TCP/IP), is a suite of communication protocols used to interconnect network devices on the internet.
Read More Define Transmission Control Protocol/Internet Protocol (TCP/ IP)