What is Pass-Through Mode?

The Pass-Through Mode allows communications from the PC to the PLC, through the HMI. This can eliminate the need to disconnect the PLC from the HMI when it is necessary to configure the HMI or PLC. Pass-through mode is only available on HMIs with an Ethernet port. See Tech Note 5047, “Using Pass-Through Mode” for…

How do I decompile and open a project file that I uploaded from my HMI to a USB Flash Drive or SD Card?

When a project is uploaded to a USB flash drive or SD card from a Maple Systems HMI, the file format will not allow you to decompile or open the file without adding an EXOB extension to the file. Step by Step instructions can be found in <a href=”/technical-notes/uploading-a-project-from-an-hmi-to-a-pc-via-a-usb-flash-drive-or-sd-card/”>Tech Note 5057, “Uploading a Project from…

How do I set up the IP Address of my Maple Systems HMI or cMT?

The IP address for the HMI is configured in the System Settings window in the HMI. When you first receive your HMI, it is running the demo project for that particular model. You will see an arrow in the bottom-right corner of the screen that gives you access to the System Toolbar when you touch…

How do I log into the built-in FTP Server on my HMI from a PC?

Maple Systems Standard HMIs, Advanced HMIs and High-Performance HMIs come with a built-in FTP server that allows you to remotely access data logs, event files, and recipe data via FTP (file transfer protocol). Please see tech note 5090, “Using the HMI’s built-in FTP Server” for instructions on how to use the built-in FTP server on…

What is EasyWatch?

EasyWatch allows users to monitor HMI and PLC address values via Ethernet from their PC, as well as invoke Macros for debugging, remote monitoring, and control. For example, after creating a Numeric Input Object in EBPro, you can set its address to LW-10, and then monitor the same address in EasyWatch. The value of LW-10…

Define Modbus TCP / IP

Modbus TCP/IP (also Modbus-TCP) is simply the Modbus RTU protocol with a TCP interface that runs on Ethernet. The Modbus messaging structure is the application protocol that defines the rules for organizing and interpreting the data independent of the data transmission medium.

How do I setup and connect my HMI to a Wi-Fi network?

Select Maple Systems HMI models feature a wireless network connection (Wi-Fi) that allows users to connect to a local wireless access point or the Internet without using an Ethernet cable. Tech Note 5121, “Wi-Fi Configuration” explains how to setup and connect your HMI to a Wi-Fi Network.

How do I upload a project from my Maple Systems HMI?

With the HMI connected to the PC via USB or Ethernet cable, click the File menu in EBPro and select Upload, or open Utility Manager and click the Upload button. (1) Select your HMI type. (2) Click Browse to select the file location and provide a name for the file. (3) Select your connection type.…

How do I setup the IP Address of my HMI on a subnet?

Whether you are connecting a Maple Systems HMI to a PLC to communicate over Ethernet, or connecting your PC to an HMI to upload or download a project over Ethernet, you must know the IP addresses of all the devices in the local area network (LAN) to ensure successful communication. In order for two devices…