Standard Headless HMI with Wi-Fi

cMT-SVR-200v2
$450.00

The cMT-SVR-200v2 is a Wi-Fi enabled HMI, great for applications requiring straight-forward HMI functionality without a touchscreen.

Monitor PLC Operations, gather PLC data, and remotely access your control system via the FREE cMT Viewer App on your smart phonetabletlaptop, or PC. If you’d like a local device for viewing, try our cMT IV Series secondary display units with built-in cMT Viewer or our Web HMI Series. Add an EasyAccess2.0 license for additional remote capabilities.

  • All the same HMI features you’re used to, just without a screen
  • Our headless HMIs are compact and can be DIN Rail mounted with ease
  • You have the option of displaying HMI screens served by a Maple headless HMI to any user with cMT Viewer installed on their Tablet, PC, or Smartphone
  • Enough horsepower to ingest, process, and publish data from dozens of local or remote devices, sensors, etc.
  • Built-in flash storage, with SD card slot for expansion and data backup
  • Supports OPC UA and CODESYS too!

Using cMT Viewer – Brief demo on how to use cMT Viewer to view Headless HMI built in screens on a tablet or smart phone 

Share the product:

System

CPU

Quad-Core RISC

Memory (RAM)

256 MB

Memory (Flash)

256 MB

RTC

Built-in

Programming Software

EBPro (Latest Version)

I/O Ports

Ethernet/LAN

10/100 Base-T x 1

CANbus

N/A

Audio Output

N/A

SD Card Slot

1 x Micro SD

USB Host Ports

USB 2.0 x 1

USB Client Ports

N/A

Wi-Fi

Yes

COM Port

1 x DE9P COM1: RS-232, COM2: RS-485 2 or 4 wire, COM3: RS-485 2 wire

HDMI Port

N/A

Video Input

N/A

Serial Ports

3

Electrical

Input Power

10.8 W

Power Isolation

Built-in

Isolation Resistance

Exceed 50 MΩ – @ 500 VDC

Input Voltage

24 ± 20% VDC

Input Current

450 mA @ 24 VDC

Mechanical

Vibration Endurance

10 to 25Hz (X, Y, Z direction 2G 30 minutes)

Enclosure Material

Plastic, charcoal grey

PCB Coating

Yes

Dimensions WxHxD

5.12 x 4.53 x 1.06 inches [130 x 115 x 27 mm]

Panel Cutout (inches) [mm]

N/A

Weight

Approx. 0.40 lbs. [0.18 kg]

Mounting

35 mm DIN Rail

Environmental

Operating Temperature

-4° ~ 131°F (-20° ~ 55°C)

Storage Temperature

-4° ~ 158°F (-20° ~ 70°C)

Relative Humidity

10% ~ 90% (non-condensing)

Certification

UL Type Rating

cULus

NEMA Rating

N/A

IP Rating

IP20

CE

Yes

UL

cULus Listed

Class 1 Div 2

N/A

ATEX

N/A

RoHS

Yes

Maple Systems HMI and PLC

Connect a Maple Systems HMI to a Maple Systems PLC

Customers who bought this product also bought:

What is the range of the Wifi on the CMT-SVR-200/202?

The WiFi spec for the cMT-SVR-200 series is IEEE 802.11 b/g/n.

802.11b/g has a range up to 150 feet (can be affected by building materials).

802.11n has a range of up to 175 feet (can be affected by building materials).

So the range depends on whether the receiver uses b, g, or n.

So to be safe, the receiver should be located in the range of 150 to 175 feet of the cMT-SVR (but the range can be affected by the building materials used).

Is Maple Systems software free?

Yes! Maple Systems programming software is completely free of charge. This includes EBPro, MAPware-7000, and MapleLogic—our flagship software tools for HMI, HMI + PLC combo, or PLC programming and configuration. There are no licensing fees, subscriptions, or activation codes required to download, install, or use these programs. Creating a free account on the Maple Systems website is all that is required.

Whether you’re developing your first HMI project or configuring a complex control system, you can access the full functionality of our software without any cost.

Maple Systems is committed to providing cost-effective solutions for our customers, and offering free software is a core part of that mission. Updates are also free, and support resources—including user manuals, video tutorials, and US-based technical support—are available at no additional cost. This makes it easy for engineers, integrators, and OEMs to start building and maintaining projects right away, without worrying about hidden expenses or recurring fees.

Why would I use a headless HMI unit instead of a touchscreen HMI?Most HMIs have a built-in touchscreen to provide feedback and allow input from on-site personnel. If that is all that’s required, a standard HMI may be sufficient. On the other hand, if you have limited panel space, no need for a touch screen, and want the convenience of monitoring and accessing your system without having to walk to where the HMI is physically located, one of our headless HMIs would be a great option. Utilize your Apple or Android smart phone or tablet to access unit remotely.
How do I activate an OPC-UA license on a cMT model?To use the OPC UA Server feature is available free on our High Performance cMT series HMIs. you you can purchase a license from Maple Systems for select Headless HMIs. This is a one-time purchase that is valid for the life of the product. After you have purchased an OPC UA license, you will receive an email from Maple Systems that contains the license serial number and activation code. You must activate the feature on the target cMT. Refer to Tech Note 5120, “Activate an OPC-UA license on a cMT-SVR” or the OPC-UA Set-up Overview manual for more information.
What if I don’t have an iPad or Smart Tablet, can I still use Wi-Fi to connect to the cMT-SVR?Definitely. Simply connect your Maple Systems cMT-SVR to a wireless router and download the cMT Viewer app to a Windows® PC with “Wi-Fi.”
Can I connect a different antenna to the Wifi-capable cMT SVRs?

Yes, you can replace the stock antenna with an aftermarket one. The antenna connector on the cMT-SVR is RPSMA Female.

Can this HMI communicate with my PLC?

Maple Systems cMT HMIs support over +400 PLC and controller communication protocols, allowing our HMIs to communicate with most common devices. Our cMT HMIs also support protocols such as Modbus TCP/IP or Modbus RTU, opening them up for use with a wide range of devices.

If you want to see the protocols that EBPro supports, visit our Controller Information Sheets page for more information. You can also download the EBPro software from our website for free, which includes simulation features. You can use these to test connections to your other devices before buying any hardware from Maple Systems.

Maple Systems cMT HMIs support 400+ Communication Protocols
Can I access my HMI from a remote network location?

Yes. Our HMIs support remote access features via the EasyAccess 2.0 application. EasyAccess provides a simple built-in solution for creating a secure VPN connection to a remote network, which will allow you to monitor and control your HMI from anywhere in the world.

Once the VPN tunnel has been established, the HMI can be accessed using the cMT Viewer application included with EBPro, or through VNC client software.

Using the EasyAccess 2.0 application does require a one-time license activation fee, which allows for 3 GB of monthly high-speed data at no additional cost. Our HMIs can also be purchased with a pre-activated license for EasyAccess 2.0 already installed.

Maple Systems remote access from anywhere in the world - EasyAccess2.0
How do I implement EasyAccess 2.0 on my Maple Systems HMI?Implementing EasyAccess 2.0 is easy. For complete instructions, refer to the EasyAccess 2.0 Manual available in our Support Center. Step 1: Create Domain Account:

An HMI must belong to a domain in order to use EasyAccess 2.0. Anyone can create a new domain for free, all you need is a valid e-mail address. The Domain Management System is the basic system used to organize and handle HMI’s under a particular domain.

An Administrator then runs the domain and adds users and HMIs to the domain. To create a new domain go to the EasyAccess 2.0 Domain Management System (DMS) website (https://account.ihmi.net). Step 2: Manage Your Domain:

When you create a domain account, you become the domain’s administrator. It’s the administrator’s responsibility to create new user accounts and to assign HMIs to specific users and HMI groups. Your domain can contain multiple HMIs, groups, and users.

Step 3: Activation:

In order to use EasyAccess 2.0, you must activate the HMI in the domain. Some HMIs have EasyAccess 2.0 pre-installed and some require purchasing an activation card.

For HMIs requiring an activation card: The HMI can be activated by purchasing an activation card from Maple Systems. The activation code (from the activation card) and the hardware key are required to activate EasyAccess 2.0 in these units. The HMI’s hardware key is located in the HMI’s system settings window. Select the EasyAccess 2.0 tab and locate the 30 digit hardware key. You may also find it on Window 76 – EasyAccess 2.0 Setting. Select “Add HMI” in the domain and enter the hardware key and activation code. When an HMI is activated by an activation code, it is automatically added to the domain under which it was activated. Open window 76 – “EasyAccess 2.0 Setting” on the HMI. With the HMI connected to the Internet, push the Start button to initiate the connection to the EasyAccess 2.0 server. For HMIs with EasyAccess 2.0 pre-installed: The HMI can be activated by obtaining a Session ID and Password from the domain. Open window 76 – “EasyAccess 2.0 Setting.” With the HMI connected to the Internet, push the Start button to initiate the connection to the EasyAccess 2.0 server. If the HMI has not been assigned to a domain yet, a Session ID and Password will be assigned to the HMI and appear on window 76. Select “Add HMI” in the domain and enter the Session ID and Password. It should now be added to the domain. Step 4: Download and Launch EasyAccess 2.0:

Download the EasyAccess 2.0 app on your PC/ iPad/ iPhone/ Android Tablet, Launch EasyAccess 2.0, enter the User ID and password. Once logged in, the program will list all HMIs assigned to this ID including all HMIs under an HMI group. Select an HMI and establish a remote connection. You can now monitor any HMI in your HMI list.

How can EasyAccess 2.0 help my business save money and reduce downtime?Maple Systems and EasyAccess 2.0 can help your business by:

Saving Money: EasyAccess 2.0 reduces travel costs including gas, airfare, and overnight hotel accommodations. It reduces the cost of man-hours paid to send personnel onsite for troubleshooting and repair, as well as reduces the number of pricey technical support phone calls. But most of all, EasyAccess 2.0 will reduce the (very) expensive cost of downtime at the plant.

Facilitating Troubleshooting: With EasyAccess 2.0, you can easily monitor and troubleshoot HMIs/PLCs from a remote location as long as an Internet connection exists. EasyAccess 2.0 manages all network settings and security issues so the user simply connects to the HMI as if they were on the local network. Instantaneously view screens or implement updates to an HMI project or PLC. Change what is seen on screen LIVE by the operator or update the project without disrupting what the operator is doing.

Reducing Down Time: Time is money. With EasyAccess 2.0 you can bring the plant up faster, minimizing expensive downtime. Consider a machine builder who sells machines with Maple HMIs installed. If a customer reports an issue, the machine builder remotely connects to the HMI using EasyAccess 2.0 and investigates the problem. He can quickly review and update the HMI project, monitor the PLC using Pass-Through mode, and even update the PLC program. With EasyAccess 2.0, you’ll enjoy the ability to resolve your problem almost as quickly as it occurs.
Can I pair a Maple HMI with a Maple PLC?Yes. Our HMIs can be paired with our PLC products via Modbus RTU or TCP. The Modbus Slave driver is configured in the PLC software, and the Modbus Master driver is configured in HMI software (EBPro). Tags can be exported and imported in both directions.
What is cMT-Viewer Application?

cMT Viewer is a client application that enables users to view and control Maple Systems cMT devices, quickly and easily. cMT Viewer runs the HMI project on the client device. Only application data is exchanged between the cMT hardware, acting as a server, and the client device – your smart phone or tablet. Monitor and control up to 50 cMT HMIs with one device!

Note: cMT Viewer is only compatible with our cMT Series.

How do I turn on Monitor Mode in cMT-Viewer?

To turn on Monitor Mode in cMT-Viewer:

1.    Click on the “gear” icon in the upper-right corner to open the Settings window.

2.       Click on the “More settings” lock icon and enter the password (default: 111111).

3.      Click on the General tab and turn on “Monitor mode.”

 

4.      Close the settings window.

5.      If you are currently logged in to an HMI, use the orange Start button in the upper-left corner of cMT-Viewer to minimize the view. You will see a small view of each HMI on the screen. If Monitor Mode has been enabled in the project on the HMI (System Parameters > General tab), Window 3 will appear in the Monitor view, otherwise it will show the startup window. (Note: If an HMI shows “Connecting” and doesn’t show Window 3, try connecting to it in EasyAccess 2.0 by clicking on the double-arrow icon.)

6.      Click on any HMI to view it in cMT-Viewer.

Can I automatically back up my projects in EBPro?

Yes. To turn automatic backup on in EBPro, click on the File menu and select Preferences. On the Project tab, check the “Generate backup of project file before save” option. This will create a backup of your project any time you save it with a *.bak1 extension.

Subsequent saves will rename the backup file with a *.bak2 and finally *.bak3 extension, so there will always be three backup files saved with *.bak1 the most recent and *.bak3 the oldest.

What are the benefits of adding Wi-Fi to my Factory?Some benefits of implementing a Wi-Fi network in your factory include:

Costs by Creating a Wireless Network: Wi-Fi can solve applications where wiring is impractical or too expensive. There’s no need to run expensive Ethernet or Serial cables throughout your plant. Add a Wi-Fi router to your network and you’re ready to go.

Flexibility in Communications and Troubleshooting: Use a Wi-Fi enabled laptop to troubleshoot your machines without having to find a network access point or carry around extra cables.

Ease of Expandability: Aside from the initial ease of setup for a Wi-Fi network, wireless networks can serve a suddenly-increased number of clients with the existing equipment. In a wired network, additional clients would require additional wiring.

Maple Systems has a variety of Wi-Fi solutions that include HMIs, Servers, Gateways, and Industrial PCs.

ERP SCADA HMI Micro Logix Wifi Diagram

How do I setup and connect my HMI to a Wi-Fi network?

Select Maple Systems HMI wifi models feature a wireless network connection (Wi-Fi) that allows users to connect to a local wireless access point or the Internet without using an Ethernet cable.

Tech Note 5121, “Wi-Fi Configuration” explains how to setup and connect your HMI to a Wi-Fi Network.

HMI Wifi Setting
Does Maple Systems offer technical support?

Yes. Maple Systems provides 100% free, US-based technical support for all customers. Our Support Center includes extensive documentation, tutorials, and resources. However, if you’re unable to find what you need, our technical support team is ready to assist. You can reach our technicians by phone at (425) 745-3229 or by email at [email protected].

When you order the cMT-SVR-200v2 the following items are included in the box:

  • cMT-SVR-200v2 Headless HMI
  • Warranty Statement
  • Installation Instruction
  • Product Flyer
  • Power Connector

Have you used this product? Share your thoughts and help others make the best choice!

Leave a Review