Applicable Model(s)

HMI500 Series
MicroOIT Series
BLU300 Series

Title

Using an Ethernet to Serial Converter for Project Downloading

Date

08/01/2005

Rev

00

P/N

0907-1092

Summary

This document describes how to download a project to an OIT over an Ethernet network.  Since the Maple Systems OIT product families do not currently offer this feature as an option, an Ethernet to Serial converter must be used.

Below is an Ethernet to Serial converter offered by a third party:


Example

Hardware Used:
VLINX (Ethernet to Serial Server) Model: ESP901 + Software CD
AirLink 5-Port 10/100Mbps Ethernet Switch
OITWare-200 software & an OIT3160 + cable 7431-0096
BlueLeaf Software & a BLU300 + cable 7431-0102

Windows for B&B Virtual Com port setup


Software Configuration

To configure Master HMIs to talk with a PLC over the Ethernet port:

1.

Click on Edit >> System Parameters and select the {PLC} tab.


2.

Select PLC Type: as “Modbus RTU TCP/IP”


3.

Select PLC I/F port: as “Ethernet”


4.

For the Multiple HMI box, select “Disable” if there is no slave HMIs.  Select Master if any HMI is to be a slave unit and if so, select “Ethernet” for the Connect I/F.


5.

Select a unique IP Address in the Local IP Address: boxes


6.

Enter in the IP Address for the PLC in the Server IP Address: boxes. Note: Whatever the network addresses are, the numbers (Octets) in the first three boxes must match for the Local IP and the Server IP.


7.

Enter 255.255.255.0 for the Subnetwork Mask.


8.

If there is a router that will be between the HMI and the PLC, enter the router IP address in the “Default Route IP address”.


More Information

For more information regarding connecting multiple HMI’s and connecting HMI’s via Ethernet, please refer to Technical notes: 1084, 1076, and 1075.